PREFACE
THE
STRONG
SUPER
TROUPER
®
III
SYSTEM
consists
of
a
direct
current
xenon
lamphouse
and
an
advanced-design
lens
mechanism
constructed
and
aligned
on
a
common
base
rail.
Operator
controls
are
easily
accessible.
The
spotlight
head
includes
a
six-color,
self-canceling
color
boomerang,
and
mounts
to
a
collapsible
base
stand
and
yoke
assembly.
A
switching
type,
solid-state
xenon
power
supply
with
a
keyed
quick-disconnect
lamphouse
cable
receptacle
completes
the
follow
spotlight
system.
ONLY
POWER
SUPPLIES
manufactured
by
Beamlight
, LLC
(dba Strong Lighting)
can
be
used
with
the
xenon
spotlight.
Current
level
adjustments
(DC
output
to
the
xenon
bulb)
are
made
at
the
power
supply
by
means
of
output
potentiometer.
For
detailed
information
regarding
installation
and
operation
of
the
xenon
power
supply,
see
the
instruction
manual
furnished
separately.
THE XENON LAMPHOUSE utilizes a deep ellipse dichroic metal reflector designed to
operate in a fixed position with a horizontally mounted xenon
lamp
as the light source.
A solid-state
DC
Pulse Igniter
is included that
requires no AC control circuit. A coated glass heat filter is located at the front
opening of the lamphouse to
reduce
the
radiant
heat
at
the
optical
system
and
color
boomerang.
THE
LAMPHOUSE
INSTRUMENT
PANEL
is
equipped
with
a
DC
ammeter
and
running
time
meter.
The
ammeter
continuously
displays
the
operating
DC
current,
and
pressing
the
VOLTS/AMP
rocker
switch
will
momentarily
indicate
the
DC
voltage
at
the
arc.
The
hour
meter
records
the
operating
hours
of
the
xenon
lamp.
The
lamp
is
ignited
and
extinguished
through
use
of
the
LAMP
rocker
switch
mounted
on
the
instrument
panel.
ONLY
XENON
LAMP
S
designed
for
horizontal
operation
should
be
used
in
this
spotlight.
The
presently
approved
ratings
for
bulbs
used
in
this
spotlight
are
1
600,
2000, 2500
and
3
000
watt,
type
“HS.”
See
the
listing
in
this
manual
for
the
approved
types
and
necessary
adapters.
ADJUSTMENT CONTROLS for positioning the xenon
lamp
inside the elliptical reflector
are
located
above
the
instrument
panel
at
the
rear
of
the
lamphouse.
The
adjustments
control
the
horizontal,
vertical,
and
focal
position
of
the
lamp
.
THE
LAMP
BLOWERS,
internally
wired
in
the
follow spot
,
operate
on
115
V.AC
and
are
required
to
keep
the
seals
on
the
lamp
at
a
safe
operating
temperature.
These
blowers
will
operate
continuously
until
power
is
turned
off
at
the
main
line
switch
to
the
xenon
power
supply.
Operation
of
the
blowers
to
cool
the
lamp
after
a
performance
will
not
be
recorded
by
the
hour
meter.
The
Super
Trouper
III
lamphouse,
when using a factory-approved, ozone-free xenon
lamp
,
requires
no
external
exhaust
system.
AN
ARC
STABILIZATION
MAGNET,
as
required
by
the lamp
manufacturers
for
the
operation
of all size lamps
,
it
is mounted to the base of the lamphouse below the reflector.
The
SOUTH
pole
of
this
permanent
magnet
is
dabbed
with
paint,
and
must
be
pointed
toward
the
left
(
non
-operator)
side
of
the
lamphouse.
ST3
/001
Содержание SUPER TROUPER III
Страница 2: ......
Страница 25: ...Analog Control Panel Printed Circuit Board Assembly No 3200866 ST3 023 ...
Страница 26: ...Super Trouper III Control Circuit ST3 024 ...
Страница 28: ...1 2 3 4 5 6 7 8 9 11 12 FIGURE 1 SUPER TROUPER III Parts List ST3 026 13 10 ...