
LAMP
ALIGNMENT & LAMPHOUSE OPERATION
PRIOR
TO
OPERATING
THE
SPOTLIGHT,
verify
the
following
conditions:
P
The
protective
cover
has
been
removed
from
the
xenon
bulb.
P
The strip heat filter is installed with the
coated
surface
facing the
lamp
.
P
The
lamphouse
access
cover
is
in
place
and
secured
using
both
P
hillips
h
ead
screws;
key
lock
secured
and
hex
head
security
screw
installed.
SEE
THE
PRECEDING
“
LAMP
INSTALLATION”
SECTION
for
instructions
detailing
the
above.
Failure
to
remove
the
lamp's
protective
cover
will
damage
or
destroy
the
xenon
lamp
.
A
missing
or
reversed
heat filter will allow radiant heat damage to the optical mechanism and lens system. The
lamphouse cover
must
be
installed
correctly
and
secured
to
actuate
all
interlock
switches
and
permit
lamp
ignition.
ENERGIZE
THE
XENON
POWER
SUPPLY
by
switching
the
circuit
breaker
on
the
side
panel
ON.
The
lamphouse
blowers
will
start
and
initiate
lamp
cooling.
The
lamp
blowers
will
operate
continuously
until
the
xenon
power
supply
is
de-energized.
PLACE
THE
LAMP
SWITCH
in
the
ON
position
and
the
lamp
will
ignite.
Allow
a
few
minutes
for
the
current
to
stabilize,
and
read
the
lamphouse
ammeter.
The
lamp
must
be
operated
within
the
current range specified by the
lamp
manufacturer. The ranges for the xenon
lamp
used are as follow:
Nominal
DO NOT
Wattage
Current
EXCEED
1600
65
A.
75
A.
2000
75
A.
85
A.
2
5
00
3
000
8
5 A.
9
5 A.
9
5 A.
105
A.
ADJUST
THE
XENON
POWER
SUPPLY
as
instructed
in
the
power
supply
manual
for
the
correct
operating
current.
A
new
xenon
lamp
is
normally
operated
at
“nominal”
current.
After
prolonged
use,
the
light
output
will
decrease
because
of
the
quartz
envelope
darkening,
a
result
of
normal
lamp
aging.
At
this
time,
the
current
output
setting
may
periodically
be
increased
to
compensate
for
bulb
aging,
but
do
not
,
at
any
time, exceed the maximum current level specified.
This adjustment over time is not necessary
with the new B3 type ballast as it is a constant power device and will
automatically
compensate for lamp
changes.
DISMOUNT
THE
COVER
PLATE
located
above
the
lamphouse
instrument
panel
by
removing the three
Torx
security
head screws
(use the Torx
d
river provided in the accessory kit).
This
exposes the control mechanism for
adjusting
the
position
of
the
xenon
lamp
.
THE
CENTER
SECTION
of
the
control
is
a
threaded
member
that
focuses
the
lamp
in
relation
to the reflector. Turning this adjustment moves the
lamp
on the horizontal plane, into or out of the
reflector.
Rotating
this
section
clockwise
moves
the
lamp
away from
the reflector. The small knurled screw
to the upper
left
of
this
section
can
be
tightened
to
lock
the
focusing
mechanism
in
place
after
the
lamp
alignment
procedure
has
been
completed.
ST3
/011
Содержание SUPER TROUPER III
Страница 2: ......
Страница 25: ...Analog Control Panel Printed Circuit Board Assembly No 3200866 ST3 023 ...
Страница 26: ...Super Trouper III Control Circuit ST3 024 ...
Страница 28: ...1 2 3 4 5 6 7 8 9 11 12 FIGURE 1 SUPER TROUPER III Parts List ST3 026 13 10 ...
Страница 38: ...FIGURE 5 ST3 036 ...