3.1.2
Remount the needle plate in reversed order but make sure that the needle plate
opening is mounted centrically to the plunger foot and that the needle plate is
mounted horizontally. Push the needle plate bow completely upwards until
threaded pin (3) (
Remounting the needle plate
Fig. 1) fits closely to the needle shaft bush.
3.1.3
The theoretic needle radius of 41.3 mm should be 0.03mm to 0.05 mm larger at
the left needle guide, 0.01 mm smaller to 0.01 mm larger at the needle glide
plate and 0.06 mm to 0.08 mm larger at the right needle guide.
Setting the needle plate (Fig. 2)
The settings should be realized with a gauge. Deviations may deteriorate the
sewing result considerably and may cause damages or premature waste of the
sewing tools.
Fig. 2