10
MA_VEB100-6_A2_180618_en
3
Hints for repair and adjustment
C A U T I O N ! Risk of injury!
Observe safety and operating instructions before realizing
any maintenance and repair works.
Failure to do so may result in heavy bodily injury.
3.1
Needle plates are set at works and can be replaced easily as complete kit.
When replacing the needle guide the dimensions have to be checked by means
of a gauge as shown in
Mounting the needle plate
Fig. 2. After removing the needle lever the gauge is
mounted to the needle shaft and senses the needle guides by turning the
handwheel.
3.1.1
Removing the needle plate (Fig. 1)
A T T E N T I O N !
Switch off machine electrically.
1.
Switch off machine electrically, cloth support arm is lifted.
2.
Swing tape feeding device upwards
3.
Remove needle and needle lever.
4.
Remove the thread trimmer's drive unit as described under
“3.9.1 Removing and remounting the thread trimmer drive (Fig. 11)” or pull
the plug only.
5.
Release needle plate fastening screws (1) and (2) and remove the
complete needle plate unit to the front.