Technical Specifications (cont’d)
1-34
“OK” Alarm Output (Managed models only)
“OK” Output
ON if P1 and P2 have power and switch software is running
Voltage
Same as switch input voltage
Maximum Current Output
0.5 Amp
Power Input
Power Input
Redundant Input Terminals
Input power (typical with
all ports active at 100
Mbps)
SE-MC2U-SC - 2.0W
SE-MC2U-ST - 2.0W
SE-SW5U - 2.0W
SE-SW5U-WT - 2.0W
SE-SW5U-SC - 3.0W
SE-SW5U-SC-WT - 3.0W
SE-SW5U-ST - 3.0W
SE-SW5U-SC-WT - 3.0W
SE-SW8U - 4.0W
SE-SW8U-WT - 4.0W
SE-SW9U-SC - 5.0W
SE-SW9U-SC-WT - 5.0W
SE-SW9U-ST - 5.0W
SE-SW9U-ST-WT - 5.0W
SE-SW5M - 3.6W
SE-SW5M-2SC - 5.6W
SE-SW5M-2ST - 5.6W
SE-SW8M - 4.3W
SE-SW8M-2SC - 6.3W
SE-SW8M-2ST - 6.3W
SE-SW8MG-4P - 12.0W - No Fiber
SE-SW8MG-4P - 15.0W - With 4 Fiber plugged in
SE-SW10MG-2P - 5.0W - No Fiber
SE-SW10MG-2P - 7.0W - With 4 Fiber plugged in
SE-SW16M - 7.0W
Input Voltage (all models)
10-30 VDC (continuous)
Reverse Power Protection
Yes
Transient Protection
15,000 watts peak
Spike Protection
5,000 watts (10x for 10 uS)
Содержание SE-MC2U-SC
Страница 1: ...Manual Number SE USER M Industrial Ethernet Switches and Media Converters USER MANUAL...
Страница 2: ......
Страница 6: ......
Страница 8: ......
Страница 14: ......
Страница 50: ......
Страница 85: ...This page intentionally left blank...
Страница 132: ...Switch 2 4 48 Chapter 4 Managed Switch Software Setup Stride Industrial Ethernet Switches User Manual 2nd Ed Rev A...
Страница 133: ...Switch 3 4 49 Chapter 4 Managed Switch Software Setup Stride Industrial Ethernet Switches User Manual 2nd Ed Rev A...
Страница 168: ......
Страница 169: ...Glossary UL C US R In This Appendix Glossary of Terms B 2 B B B Appendix Appendix Appendix...
Страница 229: ......
Страница 230: ......