CAUTION: Use with No. 1-K kerosene or No. 1 diesel fuel
OPERATING PRECAUTIONS
This is a oil/kerosene, direct-
fired, forced air heater. It’s
intended use is primarily temporary heating of buildings
under construction, alteration or repair.
Direct-Fired means that all of the combustion products
enter the heated space. Even though this heater operates
very close to 100 percent combustion efficiency, it still
produces small amounts of carbon monoxide. Carbon
monoxide (called CO) is toxic. CO can build up in a heated
space and failure to provide adequate ventilation could
result in death. The symptoms of inadequate ventilation
are:
• headache
• dizziness
• burning eyes and nose
• nausea
• dry mouth or sore throat
Be sure to follow advice about ventilation in the Safety
Precautions section.
Forced Air means that a blower or fan pushes the air
through the heater. Proper combustion depends upon this
air flow; therefore, the heater must not be revised, modified
or operated with parts removed or missing. Likewise, safety
systems must not be circumvented or modified in order to
operate the heater. When the heater is to be operated in
the presence of other people the user is responsible for
properly acquainting those present
with the safety precautions and instructions, and of the
hazards involved.
SAFETY PRECAUTIONS
1. Recommended for use with No.1-K kerosene No.1
Diesel fuel. Factory tested for use with No.2-K kerosene,
No.1 or No.2 Diesel,No.1 or No.2 fuel oil or JP8 Jet A
fuel and these fuels may be used as well. Never use
gasoline, oil drained from crank cases, naphtha, paint
thinners, alcohol or any other highly flammable fuels.
2. Check the heater thoroughly for damage. Do not operate
a damaged heater.
3. Do not modify the heater or operate a heater which has
been modified from its original condition.
4. This heater is suitable for outdoor use (not for use in
adverse weather conditions) and indoor use (only in well
ventilated areas).
5. Use in well ventilated areas, provide at least 2 sq. ft.
(0.19sq. m.) of opening near the floor and 2 sq. ft. (0.19
sq. m.) near the ceiling directly to outdoors. Increase air
openings as marked for each additional heater.
6. Always keep combustibles, like paper and wood at least
2.4 m from the heater outlet and 1.2 m from
the top, sides and inlet. Locate 1.2m from canvas or
plastic coverings and secure them to prevent flapping
movement.
7. Caution: Due to the high surface and exhaust
temperatures, adults and children must observe
clearances to avoid burns or clothing ignition. Do Not
Touch. Keep children, clothing, and combustible away.
8. Install the heater such that it is not directly exposed to
water spray, rain and / or water.
9. Never use in areas normally for habitation and /or where
children may be present.
10. Operate only on a stable, level surface.
11. Do not use with duct work. Do not restrict inlet or exit.
12. Use only with electrical power specified.
13. Use only a properly grounded 3-prong receptacle or
extension cord.
14. Do not move, handle, or service while hot or in
operation.
Models
Y015Y
Y020Y
Pressure (bar)
0.21
0.25
Max. Capacity (KW)
(Kcal/h)
(Btu/h)
15
20
12900
17500
50000
70000
Max. Fuel Consumption (L/H)
1.4
1.85
Fuel Tank Capacity (L)
20
20
Air Displacement (M
3
/H)
430
430
Motor Power (W)
160
160
Continuously Working Time
(H)
13
10
Volt/Hz/Amps
AC220-240V
50Hz 0.75A
AC220-240V
50Hz 0.75A
Net Weight
(
KG
)
17.5
17.5