ESR-Auto Plus Operator’s Manual 59
9.1 User Precautions
All ESR-Auto Plus operators should follow Universal
Precautions for handling potentially infectious materials
analyzed in this instrument. Seek immediate medical
attention in the case of exposure to biological specimens.
9.2 Electrical Equipment
The power supply of all electrical equipment is a potential
source of danger. To avoid the risk of electrical shock
and/or damage to the instrument, operators should not
open the covers of live electrical parts of the instrument.
Only authorized Streck service personnel may open the
instrument to perform maintenance or repair. In addition,
Streck recommends plugging the ESR-Auto Plus and mixer
into a power surge protector for additional protection from
power surges and fluctuations. Contact Streck Technical
Service with any questions.
9.3 Disconnect Device
Turn the power switch off before removing or reinstalling any
connectors on the ESR-Auto Plus.
To disconnect the instrument, turn the power switch to the
“Off” position and unplug the power cable from the surge
protector. It is not necessary to routinely disconnect the
instrument when it is not in use.
ESR-Auto Plus operators should follow local regulations
regarding disposal of electronic equipment.
9.4 Sample Analysis
The operator should consider all biological samples
as potentially infectious. The operator should observe
Universal Precautions and follow established laboratory
safety regulations when handling all biological samples and
blood collection sharps. Wipe up any specimen spilled on
the instrument immediately and disinfect the contaminated
surface with a 0.5% sodium hypochlorite (bleach) solution.
Biological fluids and liquid waste should not be disposed
in general waste, but should be disposed with infectious
medical waste. Compliance with waste disposal regulations
is the responsibility of the operator.
9.5 Application of Secondary Labels
Caution must be taken when applying additional patient
labels to ESR-Vacuum Tubes. Excessive label thickness,
wrinkling or flagging may increase the outer diameter of the
tube enough to wedge it in the instrument. If the operator
experiences resistance when inserting a tube containing a
secondary label, they should remove the tube before it is fully
inserted and remove the additional label before proceeding.
Chapter 9
|
Safety Precautions
Содержание ESR-Auto Plus 506
Страница 1: ...ESR Auto Plus Operator s Manual Model 506 v 1 0 2 0 ...
Страница 2: ......
Страница 6: ......
Страница 7: ...1 Introduction ...
Страница 8: ......
Страница 12: ......
Страница 13: ...2 Sample Preparation Analysis ...
Страница 14: ......
Страница 20: ......
Страница 21: ...3 Keypad Menu Overview ...
Страница 22: ......
Страница 24: ......
Страница 26: ......
Страница 36: ......
Страница 38: ......
Страница 44: ......
Страница 51: ...7 Background of the ESR Test ...
Страница 52: ......
Страница 56: ......
Страница 57: ...8 Performance Technical Specifications ...
Страница 58: ......
Страница 65: ...9 Safety Precautions ...
Страница 66: ......
Страница 69: ...10 Troubleshooting ...
Страница 70: ......
Страница 75: ...11 Quick Reference Guide ...
Страница 76: ......
Страница 80: ......
Страница 82: ......
Страница 84: ......
Страница 85: ......
Страница 86: ......