CHANGEOVER
SUMMER WINTER
SUMMER
WINTER
POWER
4.) POWER:
The centre of the display shows the set power stage.
P1: Minimum output operation
P2: Intermediate output operation
P3: Maximum output operation
The bottom row shows the set values.
R= The operating duration of the auger
P= The Pause duration of the auger
V= The Fan-power during heating operation
5.) Switching between summer and winter-mode
In summer mode, the boiler only produces domestic
hot water.
BOILER TEMPERATURE
SET POINT
DHW TEMPERATURE
SET POINT
PARALLEL OPERATION
HWS PRIORITY
HOT WATER
HEATING ONLY
Operation parameters
The following parameters are relevant for boiler operation,
pellet combustion, and flue gas temperature. The parame-
ters are set by the technician before commissioning . The
operation parameters are displayed by pressing the button
in the basic display.
Press the buttons or to set the value for the select-
ed parameter.
Press the escape button to go back to the basic display.
Press the enter button to confirm the selection.
1.) Boiler temperature set value:
2.) DHW temperature set value:
3.) Domestic Hot Water setting
Parallel operation = both heating and hot water at the
same time to set point.
BOILER CONTROL