Lisa LCD
76
Task type
Task
Task Command
Schedule update
Update schedule
us
Content update
Update playlists
Update playlists only (no tracks)
Update commercials and annoucements
up
uo
uca
Card update
Clean card
Erase card
Erase playlist
cc
ec
ep
Commercials and
announcements
Play commercial
Play annoucement
sc
sa
When an other schedule task is started, the rescheduled tasks will be deleted.
11.2
Remote control from monitoring server
When the Lisa sends remote logs to the monitoring server, there is a connection available for 15-30
seconds. Within this time frame it is possible to remotely control the device from the monitoring server.
This is done by sending the desired commands to the device. The commands that can be used are
described in
This feature is currently available on the Streamit ADP, it is planned for Streamit´s Device portal.
11.3
Telnet
A Telnet client is available on all (TCP/IP-enabled) computer platforms. Therefore, it makes sense to
support this protocol on the Lisa as well. Because a limited set of Telnet features are supported by the
Lisa, Telnet should be regarded as a command interface over port 23 for the Lisa.
When Telnet is enabled, the Lisa is constantly waits for an incoming Telnet connection. If the connection
is made, the Lisa can be controlled by sending commands. The list of available commands is listed in
the
To disconnect from the Lisa, type 'quit' (without the quotes).
Port use
Telnet on the Lisa uses port 23 (the standard port for Telnet). Since the Lisa acts as a server in this
case, inbound TCP network connections on port 23 to the Lisa are required for Telnet to work. Port-
forwarding is required when the Lisa must be reachable from outside the local area network.