12
Ridge Cap
Ridge Beam
Roof Sheet
R/H Barge Cap
L/H Barge Cap
Ridge Beam
Barge Support
Half shed width
Wall Channel
Figure 5.1
Find the centre point of the shed by halving its overall width. Align the
centre of the Ridge Beam along this point (Figure 5.1).
Figure 5.2
ROOF ASSEMBLY
Figure 5.0
10x16 self-drilling screw
Ridge Beam
Align the end of the Ridge Beam with the step of the Barge Support. Fasten
the Ridge Beam to the Barge Supports using two 10x16 self-drilling screws
through pilot holes in both ends (Figure 5.2).
Hold Down Lug
Masonry Anchor
Self-drilling screw
Bottom Channel
Anchor Spacing
Figure 4.13
The maximum spacing allowed between anchor points is determined by
the wind classification assigned to the location of your Handi-Mate.
If required, refer to your local council for advice on the wind classification
of your location.
N1 / N2 wind classifications = 1400mm maximum distance between
anchor points.
N3 wind classifications = 900mm maximum distance between
anchor points.
Note:
All Handi-Mate™ roofs are assembled in the same manner.
Ensure distance between anchor points does not exceed
maximum spacing determined by wind classification.