![Stratasys J835 Скачать руководство пользователя страница 98](http://html1.mh-extra.com/html/stratasys/j835/j835_manual_1383582098.webp)
6WUDWDV\V --
2SHUDWLQJ DQG 0DLQWDLQLQJ WKH 3ULQWHU
'2& 5HY $
$IWHUH[DPLQLQJWKH89FDOLEUDWLRQUHVXOWV
1. Click
1H[W
.
2. Remove the UV sensor and close the printer cover. After confirming the
items listed in the wizard screen, click
1H[W
.
If the results are not acceptable for quality printing, this is indicated in the
final wizard screen.
3. In the final wizard screen, click
'RQH
.
)LJXUH)LQDO89&DOLEUDWLRQ:L]DUGVFUHHQ
&DOLEUDWLQJWKH
/RDG&HOOV
Load cells are sensors that measure the weight of the material cartridges and
the waste container in the printer. It is important that you periodically check
that the weight measurements are accurate to prevent unnecessary waste of
printing materials. It is recommended that you calibrate the load cells once a
month.
7RFDOLEUDWHORDGFHOOV
1. Start the Load Cell Calibration wizard from the Options menu.
2. In the following screen, select one or more load cells that you want to
calibrate.
)LJXUH/RDGFHOOVHOHFWLRQ
3. Remove each selected cartridge from the materials cart, and click
1H[W
.