The UV lamps power up and stabilize. (This takes several minutes.) Then, the
print block passes over the sensor and the wizard compares the measured
radiation to the recommended level for each UV lamp and printing mode.
During this process, which takes 20–40 minutes, you need to monitor the
progress as displayed in the wizard screen.
)LJXUH89PHDVXUHPHQWSURJUHVV
When using a stand-alone radiation meter, reset the meter and enter the
reading (measurement) when you are prompted to do so.
)LJXUH890HDVXUHPHQWGLDORJER[
If the UV level measured is not acceptable, the wizard calibrates the UV lamp
by adjusting the current supplied to it, and then tests it again.
When all UV tests have finished, the results are displayed, showing the
condition of the lamps after calibration (see Figure 4-110 below).
)LJXUH5HVXOWVDQGFRQGLWLRQRI89ODPSVDIWHUFDOLEUDWLRQ