Installing and Using the Blood Vessel Cleaning Apparatus Kit (Optional)
Installing the BVCA Kit
Page 28
© Copyright 2019 Stratasys. All rights reserved.
Stratasys Confidential
5. Raise the liquid-level sensor with your finger, press down on the spring, and rotate the jet
plate against the left wall of the cleaning tank.
Figure 22: New jet plate placed in location of removed jet plate
6. Release the level sensor spring-clip slowly, and verify that the level sensor sits inside the
slot in the spring clip.
Figure 23: Level sensor inside spring-clip slot
Caution:
The level sensor is fragile. You must raise the level sensor and press the spring
before moving the jet plate against the side of the cleaning tank.
Level
sensor
Level sensor
spring-clip
BVCA jet
plate
Level sensor in
spring-clip slot
Jet-plate
securing screws