Operating Instructions
Draining the Tank
Page 13
© Copyright 2019 Stratasys. All rights reserved.
Stratasys Confidential
Draining the Tank
Avoid damage to the pump by draining the tank to replace the alkaline cleaning solution when
it reaches saturation point (see DOC-08380, “Working with Alkaline Cleaning Solution”).
You will also need to drain the tank before performing maintenance procedures.
Before handling the alkaline solution, read
“Alkaline Cleaning Solution Safety Instructions”
.
Draining the Tank Without Using the Drain Pump
To drain the tank without using the drain pump:
1. Close the tank cover.
2. Put on gloves, mask, and safety goggles.
3. If local regulations allow, drain the solution into a drainage pipe. Otherwise, drain the tank
into a 16-gallon (60-liter) container.
4. Open the operator panel.
5. Set the CONTROL VALVE to DRAIN TANK.
Figure 7: Operator panel - Control Valve
6. When the solution stops flowing, check that the tank is empty. If it is not completely empty,
see
“Emptying Excess Liquid from the Tank” (page 15)
Caution:
Foam is created when you drain the tank. If you are draining into a container, be careful
that it does not overflow.