4. Selection and setting of welding
parameters:
1) In the welding interface, press the right
button to enter the welding parameter setting
interface.
2) In the welding parameter setting interface,
press the knob to select the parameter as
required and rotate the knob to set a value for
the parameter.
Welding parameters available by press the knob
Welding parameters available by rotating the knob
Pre-flow
0.0-20.0(S)
Start Amp(current)
10-200(A)
Up Slope
0.0-20.0(S)
Down Slope
0.0-20.0(S)
End Amp(current)
10-200(A)
Post-flow
0.0-20.0(S)
Duty
5-95(%)
Frequency
0.5-999(Hz)
Balance
-5~+5
AC Frequency
50-250(Hz)