The  DT80  vacuum  system  is  a  medical  product  according  to  guideline  93/42/EWG.  It  is 
designed for operation with common ECG devices and offers improved safe ECG diagnostics 
combined with increased economical efficiency. 
 
The DT80 vacuum system suits for ECGs in rest as well as under physical exercise. Owing to 
the secure fixing of the electrodes it is especially advantageous in ergometry. 
 
The  DT80  vacuum  system  is  well  suited  for  the  practicing  physician  for  “regular”  use  in 
maximal 5 Exercise ECG or 20 Resting ECG per day. The system is not designed for high-use 
ECG practice and continuous operation. 
 
The vacuum electrodes are to be used according to standard measurement procedures. They are 
fixed to the patient's body by means of a defined vacuum. 
 
The  DT80  vacuum  system  is  qualified  for  ECG  diagnostics  of  adults,  teenagers  and  children 
from the age of about 7 years (depending on body size). 
 
Note 
 
The DT80 vacuum system is dedicated only for using in hospital and in medical practice. 
 
The DT80 vacuum system is not designed for continuous cardiac and circulatory monitoring 
and emergency medicine. 
 
The DT80 vacuum system is designed for temporary applications. 
 
These operating instructions are considered to be a constituent of the device and are to be kept 
therewith. 
 
Exact observance of the operating instructions is a prerequisite for the proper operation of the 
device and thus for the operator's safety. 

 

Compliance with the safety instructions provides protection against injury and prevents undue 
operation of the device. 
 
Each user of this device or each person concerned with installation, maintenance, testing or 
repair of the device should have completely read and understood these operating instructions 
before they start working.

 

 

Appropriate juridical regulations of the MPG and the MPBetreibV are to be kept. 
 
 
 
 
 
 

1.  DT80 vacuum system 

Содержание DT80 T

Страница 1: ...2019 1 Operating and safety instructions vacuum system DT80 T Strässle Co Medizintechnik GmbH Primelweg 5 D 72461 Albstadt Tel 49 0 7432 220186 Fax 49 0 7432 220189 Email info straessle co de www straessle co de Item 1000 507 ...

Страница 2: ...violation against the trademark protection law Strässle Co I O Follow instructions for use This part falls under classification CF with defibrillation protection This part falls under classification BF ON Power switch Power on Remote control Switch vacuum system to stand by mode and release vacuum Freigabe des Unterdruckes OFF Power switch Power off Remote control Switch off vacuum system Vacuum l...

Страница 3: ...ation of the support arm clamping device 3 2 Connecting the vacuum system 3 3 Connecting the distributor and the vacuum lines 3 4 Operation 4 Technical appendix 4 1 General information 4 2 Transport and storage 4 3 Operating conditions 4 4 Cleaning and disinfection of the vacuum electrodes 4 5 ECG plug in cable 4 6 Maintenance intervals 4 7 Specifications 4 8 Scope of delivery 4 9 Warranty 5 Safet...

Страница 4: ...tics of adults teenagers and children from the age of about 7 years depending on body size Note The DT80 vacuum system is dedicated only for using in hospital and in medical practice The DT80 vacuum system is not designed for continuous cardiac and circulatory monitoring and emergency medicine The DT80 vacuum system is designed for temporary applications These operating instructions are considered...

Страница 5: ...es application part Item 4000 002 electrode 1m Item 4000 004 electrode 1 3m Item 2000 159 code plate set 2 3 support arm Item 3000 178 2 Components 2 4 vacuum unit Item 3000 205 2 2 distributor Item 3000 177 2 5 control unit integrated in vacuum unit ...

Страница 6: ... robust vacuum pump including an adapted pressure vessel provides the selected pressure level A special microprocessor control unit provides for coordinated control of the overall function Power socket on off switch vacuum connector and the socket for the control unit are located at the rear of the vacuum unit 2 5 Control unit The DT80 comprises a control unit which is connected directly to the va...

Страница 7: ...rotection 3 1 1 Connecting the patient cables to the ECG device Only CE marked devices may be connected see also operating instructions ECG 3 2 Connect the vacuum unit plug in vacuum hose plug in power cable If you want to remove the vacuum hose push back the ring of the vacuum hose elbow connector in order to pull off the hose bottom of the device bottom of the device For a secure fixing in mobil...

Страница 8: ...king must be heard Only in that case the distributor is attached securely Note With excessive pulling of the distributor he becomes separated from the support arm in order to protect the construction against to large lever forces Plug in the vacuum lines into the delta distributor sockets as indicated by the codes Attach the plug in brackets The patient s cable is led with the help of the plug in ...

Страница 9: ... the selected pressure level and simultaneous flashing of the remaining LEDs will signal general readiness of the device 3 4 2 Position the support arm as desired a move up the arm b move the arm downward Note The support arm should be adjusted to a position in which the patient will not collide with the support arm the electrodes can be applied without tension the vacuum lines will not be bent op...

Страница 10: ...y individual spots with electrode spray on skin Note Use only Signa Spray Spray only individual spots in order to prevent short circuits between electrodes The electrodes may only be applied to unwounded intact skin Conductive parts of the electrode leads and connected plug in devices of the application parts including the electrode must not touch other conductive parts including earth The electro...

Страница 11: ...icated by flashing the respective set pressure level 4 1 General information The device is suitable for continuous operation Integrated defibrillation protection protects subsequent devices High frequency fields and emissions may influence the quality of the ECG measurements The DT80 ECG vacuum unit is provided with a CE label according to the guideline given by the Council on Medical Products 93 ...

Страница 12: ...of cleaning cycles under operating conditions has no negative impact on durability Cleaning increases the life and ensures consistently good signal quick disinfection and cleaning cloths 100 pcs Item 1000 352 250ml quick disinfectant and detergent Item 1000 354 5l quick disinfectant and detergent Item 1000 351 750ml disinfectant foam Item 1000 327 External spraying of the hoses and suction cups Us...

Страница 13: ...nsions 162x190x75 w x l x h vacuum unit only 4 8 Scope of delivery depending on model version Power cable 1000 099 removable part Vacuum unit with control unit 3000 205 Holder for control unit 2000 237 accessory Distributor 3000 177 Support arm 3000 178 Clips for cable adjustment 1000 596 2 accessories Electrode set 6x1m 4xEXT 1 3m 4000 005 removable parts alternatively electrodes 10x1m or 10x1 3m...

Страница 14: ...his device is not allowed without prior consent by the manufacturer Strässle Co Medizintechnik GmbH Electrodes may not be brought in contact with oxidising acids or Cyanid solutions The specifications of vacuum level under 3 4 3 are to be kept Too highly selected vacuum levels can lead to blisters on the skin To protect the skin especially sensitive patients who are repeat measurements with the sa...

Отзывы: