CIRCUIT BREAKER MODELS (MLO - MAIN LUG ONLY) 

Some models of the Contact Low Voltage Lighting Control Panel include internal branch circuit breakers. In this 
case, a breaker access door is included on the front panel. MLO option is only available on the following models: 

MODEL

DESCRIPTION

VOLTAGE

76921C

Relay Insert Panel with breakers, 24-way

120V 

76922C

Relay Insert Panel with breakers, 36-way

120V 

76923C

Relay Insert Panel with breakers,48-way

120V 

76931C

Relay Insert Panel with breakers, 24-way

277V 

76932C

Relay Insert Panel with breakers, 36-way

277V 

76933C

Relay Insert Panel with breakers,42-way

277V

FIGURE 2. 

 LIGHTING CONTROL PANEL WITH INTERNAL CIRCUIT BREAKERS 

NOTE

: The 24-Circuit Breaker Panel is shown in this example, however, components are typical for all breaker 

models. 

INSTALLATION OVERVIEW

The following steps are required to successfully install this product:

Step 1. 

Review this document completely before starting the installation.

Step 2. 

Unpack and inspect equipment. Compare the equipment you received with your packing list. If these 
do not match, contact Strand Lighting Customer Service at 1-214-647-7880.

Step 3. 

Gather tools. Refer to Tools List below.

Step 4. 

Choose an appropriate location for installation. Refer to Locations and Clearances below.

Step 5. 

Plan the wire routings and connection order. Decide where the Feed, Load, and Control wiring will 

FRONT PANEL 

INTERIOR VIEW 

1)
2)
3)
4)

Breaker Access Door 
Breakers 
Circuits 1-12 
Circuits 13-24 

Содержание 76910

Страница 1: ...12 CIRCUIT 24 CIRCUIT 36 CIRCUIT 48 CIRCUIT CONTACT LIGHTING CONTROL PANEL USER MANUAL...

Страница 2: ...Breakers 42 way For complete speci cations refer to Appendix B Speci cations on page 26 For Options and Accessories see Contact Options and Accessories on page 34 Please read all instructions before i...

Страница 3: ...TE The Contact 24 Circuit Panel is shown in this example however components are typical for all models Installation Operation Guide Contact Lighting Control Panel 2 OVERVIEW 7 FRONT PANEL 1 DETAIL A L...

Страница 4: ...277V FIGURE 2 LIGHTING CONTROL PANEL WITH INTERNAL CIRCUIT BREAKERS NOTE The 24 Circuit Breaker Panel is shown in this example however components are typical for all breaker models INSTALLATION OVERV...

Страница 5: ...at may be required for this installation Drill for mounting holes Pencil Wire stripper Digital voltmeter RMS Ratchet and assorted sockets Small at screwdriver Hammer for removing knockouts Knife Heat...

Страница 6: ...omponents are typical for all models CONNECTING LINE LOAD WIRING WARNING You must have access to a main circuit breaker or other power disconnect device before installing any wiring Be sure that power...

Страница 7: ...ler PCB for connection of control wiring The Controller PCB also contains jumpers for termination of DMX512 signal and connection to Auxiliary panels To connect control wiring Step 1 Route control wir...

Страница 8: ...Orange White Color White Orange Orange White Green Green White Blue Blue White Brown Brown Vision net Wiring Belden 1583A Pin No 1 2 3 4 5 6 7 8 9 Function Data Data Ground 24VDC Ground 24VDC Ground...

Страница 9: ...Escape button FIGURE 6 LCD MENU LED Status Indications LED CONDITION MEANING POWER Flashing Green Indicates power is active to the Rack Control Module RCM processor FAULT Flashing or Steady Red Indica...

Страница 10: ...nt N A Displays which preset a relay is assigned to Relay with Errors N A Displays the number of relays with an error Firmware N A Displays Processor s current firmware version as 86XXXX vX XX RELAY S...

Страница 11: ...ld take precedence unless the Primary source is not present at which time the Fallback source would take precedence Fallback vs Fallback in the this case the source with the highest level takes preced...

Страница 12: ...channels to specific relays TIME CLOCK FUNCTIONS SUB MENU OPTIONS COMMENTS View Current Events Press Enter to view scroll all programmed events Allows users to scroll through all programmed events Ad...

Страница 13: ...pli ed keypad addressing system using Vision Net button stations without the need of a computer Vision Net Designer not required When a keypad is in its Factory Default Mode its Room assignment can be...

Страница 14: ...station keypad and hold for three seconds The address is now assigned to that station Step 5 Walk to second Room where a button station is located Press any button on the station keypad and hold for t...

Страница 15: ...blinking off to indicate current relays assigned to that Room If a relay is not assigned to that Room its LED will not be illuminated Step 5 Once all relays are set as desired press Enter button to Sa...

Страница 16: ...see Event de ni tion above To Add an Action Step 1 At CLOCK CONFIG menu navigate to Add Edit Time Clock Events and press Enter button Step 2 At ADD NEW ACTION screen con gure action options Preset Ro...

Страница 17: ...ge parameters Use LEFT and RIGHT arrow button to navigate be tween parameters month day year Step 4 When all edits to Set Date are complete press Enter button to save con guration NOTE Pressing Escape...

Страница 18: ...ational Recognized Testing Laboratory Transfer Device To trigger the Contact Panel to enter the emergency mode a control signal Contact Closure open must be provided to the panel and connected to the...

Страница 19: ...drawing set if provided DO NOT convert these cables to home runs 5 DMX512 cable runs should all be in metal conduit Runs in exposed areas must be in metal conduit Maximum cable run should not exceed...

Страница 20: ...he loose conductors Step 6 Strip 1 8 inch of the insulation from each of the conductors Step 7 Terminate the conductors on the terminal block or solder the terminals as speci ed Step 8 For solder conn...

Страница 21: ...aximum length of any segment cable run including device cables between Hub or Switch and Node is 90 meters Maximum network diameter distance between any two Nodes is 180 meters MASTER AUXILIARY WIRING...

Страница 22: ...on Non Dim Fluo rescent HID LED Control via Internal Astronomical Timeclock Vision Net Control Stations Vision Net Occupancy Sensors Vision Net Photocells DMX512 ShowNet Operating Voltage Mix 120VAC 2...

Страница 23: ...Low Voltage Electronic Low Voltage Neon Non Dim Fluo rescent HID LED Control via Internal Astronomical Timeclock Vision Net Control Stations Vision Net Occupancy Sensors Vision Net Photocells DMX512...

Страница 24: ...c Low Voltage Electronic Low Voltage Neon Non Dim Fluo rescent HID LED Control via Internal Astronomical Timeclock Vision Net Control Stations Vision Net Occupancy Sensors Vision Net Photocells DMX512...

Страница 25: ...c Low Voltage Electronic Low Voltage Neon Non Dim Fluo rescent HID LED Control via Internal Astronomical Timeclock Vision Net Control Stations Vision Net Occupancy Sensors Vision Net Photocells DMX512...

Страница 26: ...g 14 000AIC 277VAC Load Types Incandescent Tungsten Halogen Magnetic Low Voltage Electronic Low Voltage Neon Non Dim Fluo rescent HID LED Control via Internal Astronomical Timeclock Vision Net Control...

Страница 27: ...ting 14 000AIC 277VAC Load Types Incandescent Tungsten Halogen Magnetic Low Voltage Electronic Low Voltage Neon Non Dim Fluo rescent HID LED Control via Internal Astronomical Timeclock Vision Net Cont...

Страница 28: ...Rating 14 000AIC 120VAC Load Types Incandescent Tungsten Halogen Magnetic Low Voltage Electronic Low Voltage Neon Non Dim Fluo rescent HID LED Control via Internal Astronomical Timeclock Vision Net Co...

Страница 29: ...Rating 14 000AIC 277VAC Load Types Incandescent Tungsten Halogen Magnetic Low Voltage Electronic Low Voltage Neon Non Dim Fluo rescent HID LED Control via Internal Astronomical Timeclock Vision Net Co...

Страница 30: ...PUT FOR 277V POWER SUPPLIES 1 2 3 Catalog Description 76931C Relay Insert Panel w Breakers 24 way 76932C Relay Insert Panel w Breakers 36 way 76933C Relay Insert Panel w Breakers 42 way CONTACT RELAY...

Страница 31: ...76990 Barrier Kit RELAY OPTIONS Catalog Description 76991 Relay 1 pole 76992 Relay 2 pole occupies two slots 347V POWER SUPPLY OPTION Catalog Description 76951 277 347V Power Supply for control electr...

Страница 32: ...P United Kingdom Tel 44 020 8965 3209 CONTACT LIGHTING CONTROL PANEL USER MANUAL DOCUMENT NUMBER 2 450330 010B VERSION DATE JULY 6 2020 2020 Signify Holding All rights reserved All trademarks are owne...

Отзывы: