![Strand Lighting 200 Series Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/strand-lighting/200-series/200-series_operation-manual_1383394020.webp)
Page 20
Strand 200 Console Manual
Crossfade between Submasters
Aside from the normal two fader crossfade, in submaster mode the
operator can crossfade in sequence. Make sure the preset A & B
masters are in the UP position.
Set the
In – Time Fade
fader to the desired fade in time and set the
Out –
Time Fade
to the desired fade out time.
Move the preset A & B masters down (the first
recorded fader’s LED will begin
Now move the preset A & B masters up to
fade in the first scene (the first recorded
faders LED will stop flashing and the scene
will fade in.
When the fade is complete the second
recorded fader’s LED
will begin flashing green). Repeat down and up master action to continue crossfading
between scenes. This will crossfade the second scene with the first one. Repeating the
process will crossfade all available scenes until it reaches the last scene of page two and
then returns to the first recorded scene of page one again.
Additional Information for Submaster Crossfading
•
To stop the crossfade, move only preset A master down and then up. This will fade
out the last output scene.
•
Changing mode will also stop the crossfade immediately and take out the last fade
output and is not recommended.
•
Any empty submasters, submasters with effects or submasters that already have a
level, will be ignored. For example, If any of the submasters are already in the up
position (i.e. outputting a level), the sequential crossfade will start from the scene
immediately after the highest outputting fader (i.e. If fader 1,3,5 are up, the crossfade
will start from scene 6).
•
The LCD screen will show the fader percentage values for both the fade in and fade
out as the fade is occurring.
Note: See
Crossfade Start Scene Option
for changing the submaster that is crossfaded first.
flashing green)