STRALUS SLLS001 Скачать руководство пользователя страница 6

Essential Information

1

6

1.2   Intended Use

This product has been developed and tested for use 
under specific conditions. These are defined as the 
conditions of Normal Use.

Use of this product outside of Normal Use may  
create a hazardous situation for the resident, 
operator or another party. To avoid this ensure the 
product is only used in accordance to the following 
conditions and all instructions in this document. 

— 

Intended Resident:

 This bed is intended for a  

 

resident over 12 years old and taller than 139cm.

— 

Intended Environment:

 This product should only  

 

be used in a facility where medical supervision  

 

and care is available. This includes nursing  

 

homes and rehabilitation centres. This product  

 

must not be used in an acute care, hospital or  

 

domestic environment.   

— 

Locked Castors:

 When operating the bed, with  

 

or without a resident, the bed castors must    

 

remain locked.

— 

200kg Safe Working Load (SWL):

 The load on  

 

the bed can never exceed 200kg. This includes  

 

accessories, mattress and style packs. The load  

 

must be distributed evenly.

— 

2 Minute Duty Cycle:

 Continuous operation  

 

of bed is limited to 2 minutes. An 18 minute  

 

cool down is required for every 2 minutes of  

 

continuous use.  

— 

Annual Servicing:

 This product requires regular  

 

maintenance with a service check carried out by  

 

a qualified service technician. A service interval  

 

of 12 months is required to maintain good  

 

working order, and uphold the standard product  

 

warranty.  

— 

Mattress:

 This product may only be used with  

 

mattresses of the size specified in Section 2.4.

— 

User Training:

 Operators of this product must  

 

be familiar with all conditions and parameters  

 

presented by this document.

Содержание SLLS001

Страница 1: ...Important Please read before operation Model SLLS001 User Manual S Line Bed...

Страница 2: ...2...

Страница 3: ...10 2 2 Hand Control 11 2 3 Style Pack 11 2 4 Mattress 12 2 5 Castors and Brakes 13 2 6 Battery Optional 13 2 7 Wall Bumper 14 2 8 Electronics and Software 14 2 9 Accessories 14 3 Using your Stralus Ca...

Страница 4: ...Essential Information 1 4 Thank you for choosing Stralus Forward thinking healthcare products engineered and designed in Australia...

Страница 5: ...BC TGA Number ARTG 239572 Underbed Clearance 130mm when bed is raised above 350mm Castor Braking 3 Positions Total Brake Neutral and Direction Lock Electrical Power In 230V AC 50 60 Hz Power Out 24V D...

Страница 6: ...d in an acute care hospital or domestic environment Locked Castors When operating the bed with or without a resident the bed castors must remain locked 200kg Safe Working Load SWL The load on the bed...

Страница 7: ...ing to conditions of Normal use Resident Transportation This product is not intended for transportation of residents The product should only be moved when in the transportation position Multiple resid...

Страница 8: ...e operator is unsure of the environment they must consult their facility manager Not Supporting a Resident The bed is not supporting a resident or any other person in any manner This includes lying si...

Страница 9: ...efined by this document It is the responsibility of the operator to obtain and read the latest version of all documentation Stralus reserves the right to make design and documentation modifications at...

Страница 10: ...Functions and Features 2 10 2 1 Overview BRAKE PEDAL KNEE BREAK FOOTREST BACKREST HEADBOARD SIDEBOARD FOOTBOARD CENTRAL LOCKING CASTORS WITH DIRECTION LOCK...

Страница 11: ...ice of Style Packs designed to improve the resident s experience The Style Pack consists of Headboard Footboard and Sideboards Please contact your Stralus representative for information on Style Pack...

Страница 12: ...sizes are recommended for use with the Stralus Care Bed Single Mattress Approved Sizes Length mm Width mm Height mm 1960 865 125 1960 865 150 1960 865 200 King Single Mattress Approved Sizes Length m...

Страница 13: ...with an optional battery backup pack that allows operation without mains power At your bed s Safe Working Load the battery will last for 15 minutes of continuous operation This is enough to raise and...

Страница 14: ...ved for applications within medical facilities This system complies with the EMC directive 2004 108 EC Software used by this system has been designed in accordance with IEC 60601 1 4 Software for Medi...

Страница 15: ...3 1 Getting Started Before using your new Stralus Care Bed please make sure the following items have been assembled correctly as shown Headboard Fasten Headboard to bed frame as shown Footboard Fasten...

Страница 16: ...Using your Stralus Care Bed 3 16 Sideboard Fasten Sideboard to bed frame as shown Plug in Hand Pendant Control The Hand Pendant Control should be plugged in as shown HAND PENDANT CONTROL CABLE...

Страница 17: ...e first time Wall Bumper If the bed is positioned with the Headboard against a wall ensure the bumper bar is resting on the floor against the wall to avoid a collision with the wall when the bed is lo...

Страница 18: ...nitored regularly 3 2 Everyday Use Pre Use Checklist Check brakes are engaged and the bed is stable Check that entrapment zones specific to function are clear of any people limbs animals and or object...

Страница 19: ...ator must check that the area under bed and behind the headboard are clear of People Limbs Any other objects Back Rest Back Rest section of the bed can be raised using the Hand Pendant Control WARNING...

Страница 20: ...t the area between the knee break and the upper frame is clear of People Limbs Any other objects Auto Contour Back Rest and Knee Break can be simultaneously raised using the Hand Pendant Control WARNI...

Страница 21: ...ered as shown below WARNING RISK OF ENTRAPMENT The operator should avoid reaching under the knee break or footrest when it is loaded To raise foot section Lift foot end and allow ratchet to click and...

Страница 22: ...irection lock lift the pedal up highest position The operator should hear an audible click as the pedal enters each braking mode Cable Storage When storing or transporting your Stralus bed ensure the...

Страница 23: ...he head end into a direction in line with the side of the bed to assist in steering the bed during transportation Ensure the area under the bed and surrounding areas are clear of people or obstacles b...

Страница 24: ...Care Bed 3 24 3 4 End of Product Life Disposal of electronics metals and plastics is governed by varying regional regulations Consult your sales representative for the best practice and dispose of pr...

Страница 25: ...ents Dry all components Reconnect main power retract all actuators and store Safety Notes This product cannot be cleaned by an auto washer or water jet cleaner Do not clean with a steam cleaner Do not...

Страница 26: ...also a condition of this product s warranty see Appendix A2 5 2 Irregular Maintenance It is possible that your Stralus product may require maintenance before the next scheduled service Such servicing...

Страница 27: ...wer lead If unplugged plug power up or down and optional battery is flat is plugged into mains lead into mains power power Allow 3 hours to charge battery if fitted Actuator is faulty Contact your sal...

Страница 28: ...ator wear Sound is persistent only Contact your sales ticking sound when actuator is being representative or a qualified used Stralus service technician Squeaking or Mechanism wear Sound is persistent...

Страница 29: ...ease contact your supplier A 2 Copyright Information All information contained within this documentation is the intellectual property of Stralus Pty Ltd This document is to be considered part of a Str...

Страница 30: ...Notes 8 30...

Страница 31: ......

Страница 32: ...T 03 8833 7850 stralus com au Please email any suggestions or queries to development stralus com au...

Отзывы: