3.5" 3Gbps-Speed SATA Mirror Drive Model User’s Manual
13. Confirm that the front levers are closed.
14. Several seconds after replacing the drive unit, data reconstruction will start. The drive status
indicator of the replacement drive unit will flash orange (@1 second interval).
Important
Do not remove the drive unit while data reconstruction is underway.
15. During data reconstruction, the drive status indicator of the replaced drive will flash orange, while the
drive status indicator of the fully functional drive unit will light green. The access indicator will not
light.
16. When data reconstruction is complete, the drive status indicator will go out.
17. If the drive status indicator of the replaced drive unit turns orange once again (not flashing), turn off
the power, pull out the replaced drive unit and repeat the procedure beginning from step 10.
29