3.5" 3Gbps-Speed SATA Mirror Drive Model User’s Manual 

 

4.1.1  Operating Mode (Do not change) 

 
The operating mode switches (S1-1

S1-2

S1-3

S1-4 & S2-4) are set to normal mode (mirror mode). Do 

not change this setting. 

 

 

Important 

Changing the operation mode switches will result in loss of data. 

 
 
 

4.1.2  Write Cache Mode 

 
This bit sets the write cache mode. If set to "ENABLE" (Default Setting meaning Write Cache Enabled), 
the 

SATA Mirror Drive

 will signal completion of command processing to the host computer when the 

data has been written to cache memory. If set to “ON”, the 

SATA Mirror Drive

 will signal completion of 

command processing to the host computer when data is actually written to the drive unit. 

 

Always observe the shutdown procedure specified for the host 
computer’s operating system. In delicate situations, try to wait at 
least 10 seconds to be sure that both the access indicator and the 
drive status indicator have stopped flashing before shutting off the 
power. Turning off the power while the access indicator or the drive 
status indicator remains lit may result in loss of data currently located 
in cache memory. 

 

Important

 

 
 
 

4.1.3 Revival Reconstruction 

 
If the bit is set to "ENABLE" (Default Setting meaning Revival Reconstruction Enabled), the 

SATA 

Mirror Drive

 will attempt to do data reconstruction after Error Recovery Procedure fails while in Retry 

Mode. The 

SATA Mirror Drive

 will not remain in Degraded Mode but instead, will automatically do data 

reconstruction to trying to revive the drive up to two times. 
 
 
 

4.1.4 Buzzer 

 
If the bit is set to "ENABLE" (Default Setting meaning Buzzer Enabled), the buzzer will sound when any 
error is detected. In the event of a drive unit failure, the buzzer will continue to sound until the failed drive 
unit is replaced. The buzzer can be stopped if the switch position is changed to “ON”. 
Set back the buzzer to "OFF" after the failed drive unit has been replaced. 
When an external bracket is used for the 5" Drive Bay installation, please make sure that S2-3 setting of 
the Dip Switch is set to “ENABLE”. The buzzer sound can be turned ON and OFF through the Buzzer 
switch in the external bracket. If the buzzer is turned OFF prior to drive replacement, slide it back to ON 
after the new drive unit has been inserted. 
 

 

10

Содержание SVRB-U Series

Страница 1: ...3 5 SATA Mirror Drive 3Gbps Speed Model SVRB U Series User s Manual P N A203955 Revision 1 1...

Страница 2: ...3 5 3Gbps Speed SATA Mirror Drive Model User s Manual This page is intentionally left blank...

Страница 3: ...ve please retain the packaging materials in case you need to ship the SATA Mirror Drive in the future This product is sealed in an antistatic and moisture proof bag before shipping Open the bag only w...

Страница 4: ...ious injury to the user or severe damage to the product Caution Indicates a potentially hazardous situation that may result in serious injury to the user or damage to the product Important Indicates i...

Страница 5: ...fy this product STR V cannot guarantee the performance or safety of any product that has been repaired by the customer or by an unauthorized third party Repairing by your self may result in fire elect...

Страница 6: ...ternal components of the SATA Mirror Drive y Do not turn on the power immediately after turning it off or turn off the power immediately after turning it on Leave at least 20 seconds in between succes...

Страница 7: ...ng the shutdown procedure for your host computer The SATA Mirror Drive uses cache memory to store the data frequently accessed from the HDD Except in emergencies you must follow the operating system s...

Страница 8: ...other static sensitive devices touch a metal object such as the metal enclosure of the host computer to discharge any static electricity from your body y Always handle components carefully Never touch...

Страница 9: ...puter ensure that the drive unit is installed horizontally as in A below Do not install the unit vertically i e with the connector facing either up or down as in B Furthermore when installing the unit...

Страница 10: ...Part Names 4 2 2 Dimensions 5 2 2 1 SATA Mirror Drive 5 2 2 2 5 inch Bay Mirror Drive Installation Attachment 6 3 Installation 7 3 1 DIP Switch Settings 7 3 2 Mounting in the Host Computer 7 3 3 Cabl...

Страница 11: ...e Unit 24 6 3 1 Controller Unit Replacement Procedures Both Drives Are Good 25 6 3 2 Controller Unit Replacement Procedures One Drive Unit Has Failed 27 6 4 Other problems 30 Appendix A Specifications...

Страница 12: ...the SATA Mirror Drive can be used like any other standard Serial AT HDD No special device drivers needed Compatible with most operating systems z Compact size 101 6 mm x 145 0 mm x 40 0 mm W x L x H z...

Страница 13: ...wer Turning off the power while the access indicator or the drive status indicator is still on may result in loss of data currently located in cache memory Important 1 4 Data Rebuilding If a failed dr...

Страница 14: ...led drive The function Revival Reconstruction turns the power of the drive OFF ON And if the drive status becomes ready reconstruction is started Revival reconstruction is executed up to two times Aft...

Страница 15: ...Names Drive unit 2 status indicator MODEL SVRB U080SA S N B800001 EC YB Model name Version DIP switch Power connector Contoroller unit Access indicator Status indicator Drive unit 1 status indicator...

Страница 16: ...l User s Manual 2 2 Dimensions 2 2 1 SATA Mirror Drive Unit mm ACC RR DMA BZ CA 1 2 PUSH PUSH 145 0 101 6 40 6 4 41 6 60 16 9 3 2 95 2 3 2 44 5 61 3 6 32UNC X3 Same on opposite side Mounting screw hol...

Страница 17: ...TA Mirror Drive Model User s Manual 2 2 2 5 inch Bay Mirror Drive Installation Attachment Unit mm ACC RR DMA BZ CA 1 2 PUSH PUSH 4 6 32UNC X4 Mounting screw holes Same on opposite side 79 2 52 5 9 9 1...

Страница 18: ...t the power supply of the host computer is turned off 3 2 Mounting in the Host Computer When mounting in the host computer use the attached mounting screws and the specified mounting holes The mountin...

Страница 19: ...h drive unit to confirm that these check if the host computer detects the unit Power connector SerialATA connector 3 4 Turning on The Main Power B are firmly inserted and verify if the lever lock is f...

Страница 20: ...set to maximize its performance DIP Switch Functions Default Switch position S1 1 S1 2 S1 3 Mode Bit 1 2 3 Enable Normal S1 4 Reserved 1 Enable S2 1 Write Cache Enable Write Back S2 2 Revival Reconst...

Страница 21: ...status indicator remains lit may result in loss of data currently located in cache memory Important 4 1 3 Revival Reconstruction If the bit is set to ENABLE Default Setting meaning Revival Reconstruct...

Страница 22: ...en simultaneously Any of the above 5 1 2 Drive Status Indicator Green 1 When the power is turned on 1 2 Processing a command from the host computer 3 Processing an internal command Either of the above...

Страница 23: ...the event of a failure the buzzer will beep at the interval specified below Drive unit 1 failed Beep Beep Buzzer 0 3s 3 2s Drive unit 2 failed Beep Beep Buzzer 0 3s 3 1s 0 3s 0 3s Beep Beep System st...

Страница 24: ...follows Signal Connector Pin Assignment 1 GND 2 5VDC 3 Status Bit 2 4 Status Bit 1 5 Status Bit 0 6 GND CN13 Status output is transmitted in 3 bit signals as follows Bit 2 Bit 1 Bit 0 Status 0 L L L...

Страница 25: ...specification Output High Voltage VDC max 3 3V Default 5 0V Option Voltage Selectable Through S3 Output Low Voltage VDC max 0 4V Output Sink Low Current max 20mA Current Output Source High Current max...

Страница 26: ...t 1 Normal operation Orange Drive unit 1 failure Replace the drive unit 1 with a new drive unit Orange Drive unit 2 failure Replace the drive unit 2 with a new drive unit Orange Controller unit failur...

Страница 27: ...warranty does not cover any damage encountered due to replacement with a non specified HDD Furthermore STR V is not held liable for any consequence resulting from the use of an undesignated HDD If th...

Страница 28: ...ive unit s lever and then pull out the drive unit 4 Close the front lever and insert the replacement unit Push the replacement drive firmly into the unit with both hands 5 Confirm that the front lever...

Страница 29: ...dicator will not light 8 When data reconstruction is complete the drive status indicator will go out 9 If the drive status indicator of the replaced drive unit turns orange once again repeat the proce...

Страница 30: ...it through the drive status indicator or buzzer 3 Turn off the power supply of the host computer 4 Push the PUSH mark on the front lever and open the lever 5 Pull the failed drive unit s lever and the...

Страница 31: ...onal drive unit will light green The access indicator will not light 11 When data reconstruction is complete the drive status indicator will go out 12 If the drive status indicator of the replaced dri...

Страница 32: ...new drive units as specified in Appendix D Replacement Parts 2 Turn off the power supply of the host computer 3 The drive unit to be replaced first should be the one that failed first Push the PUSH ma...

Страница 33: ...cond interval Important Do not remove the drive unit while data reconstruction is underway 9 During data reconstruction the drive status indicator of the replacement drive will flash orange while the...

Страница 34: ...ment drive unit will flash orange 1 second interval Important Do not remove the drive unit while data reconstruction is underway 16 During data reconstruction the drive status indicator of the replace...

Страница 35: ...its status 1 When both drive units are functioning normally Switch over both drive units to a new controller unit Ensure that each drive unit is inserted into exactly the same drive bays as before 2 W...

Страница 36: ...Drive from the host computer 4 Push the PUSH mark on the front lever and open the lever 5 Release both drive units lever one after the other and then pull it out Pull out drive unit 1 Pull out drive u...

Страница 37: ...el User s Manual 7 Confirm that the front lever is closed 8 Re install the SATA Mirror Drive back into the host computer connect the SATA Host cable and then finally the SATA power cable 9 Turn on the...

Страница 38: ...d the SATA internal power cable Then remove the SATA Mirror Drive from the host computer 5 Push the PUSH mark on the front lever and open the lever 6 Pull out both drive units one after the other Pull...

Страница 39: ...e host computer connect the SATA Host cable and then finally the SATA power cable 10 Turn on the power supply of the host computer 11 Confirm that the host computer recognizes the SATA Mirror Drive 12...

Страница 40: ...econstruction is underway 15 During data reconstruction the drive status indicator of the replaced drive will flash orange while the drive status indicator of the fully functional drive unit will ligh...

Страница 41: ...ms If the problem persists even after you have replaced the drive unit or the controller unit please contact your distributor In addition if you also happen to encounter other types of problems not me...

Страница 42: ...nt 146 0mm x 146 0mm x 43 0mm SATA Mirror Drive 700 g Weight max 5 inch Bay SATA Drive Installation Attachment 900 g Voltage VCC 4 85 VDC 5 25VDC Power supply ripple max 1 100mV p p 0 20MHz Power star...

Страница 43: ...3 5 3Gbps Speed SATA Mirror Drive Model User s Manual Appendix B Accessories The SATA Mirror Drive SVRB U Series is shipped with following accessories y Mounting screws 4pcs 32...

Страница 44: ...Switch Settings Default Setting Enable Function Mode SW No DIP SW S1 1 Enable S1 2 Enable Mode Mirror Mode S1 3 Enable Reserved S1 4 Enable Write Cache Enable Write Back S2 1 Enable Revival Reconstruc...

Страница 45: ...D Replacement Parts The following are supplied as user replaceable parts Part name Part number A203958 160 GB drive unit Replacement drive unit for SVRB U160SA SA1 A204060 Replacement controller unit...

Страница 46: ...For more information about this product please contact your distributor Distributor s information Product Records Model Name SVRB U Revision YB Serial Number Manufacturer This product is manufactured...

Отзывы: