This information is relevent to the
following appliances:
Stoves 1100DFa
Stoves Precision 1100DFa
Stoves Heritage 1100DF
Data badge -
Located on the lower part
of the front frame.
Type of gas -
This cooker must only be
used with either Natural gas only or LP gas
only, as specified on the appliance data
badge.
Gas category
Natural gas -
I
2H
, LP gas -
I
3+
Pressure setting
G20 Natural gas @ 20 mbar
G30 Butane @ 28-30 mbar
G31 Propane @ 37 mbar
Aeration -
Fixed
Appliance class -
Class 1, freestanding
cooker
Electrical supply
220 - 240V ~ 50Hz
Warning:
This cooker must be earthed.
Spark generators
Mains powered 7 outlet, controlled by a
single switch at the left of the fascia to
individual electrodes.
Hob -
Burners have burner heads and
caps which are removable for cleaning.
Concealed electrodes to each burner.
Countries of destination
GB - Great Britain, IE - Ireland
25
Hotplate burner / Element
Nominal
Injector
Butane
Propane
Rate Qn
marking
g/h
g/h
Natural
Hob - small (2)
1.0kW
77
-
-
Gas
Hob - medium (3)
2.0kW
104
-
-
Hob - large (1)
3.0kW
129
-
-
Hob - wok (1)
3.5kW
121 & 63
-
-
Total heat input
Qn 14.5kW
LP Gas
Hob - small (2)
1.0kW
50
73
72
Hob - medium (3)
2.0kW
70
145
143
Hob - large (1)
3.0kW
87
218
215
Hob - wok (1)
3.5kW
87 & 35
254
250
Total heat input
Qn 14.5kW
-
1054
1037
Electric
Grill (dual)
2575W
-
-
-
@ 230V
Grill (single)
1655W
-
-
-
Conventional oven
1920W
-
-
-
Fan oven
2300W
-
-
-
Stir fan
30W
-
-
-
Cooling fan
10W
-
-
-
Oven lights (if fitted)
25W each
-
-
-
Maximum load
6885W
TECHNICAL DATA
25211 03 - Precision 1100DFa 5/8/04 11:46 AM Page 27
Содержание Heritage 1100DF
Страница 28: ...26 NOTES...
Страница 29: ...27 NOTES...
Страница 31: ......
Страница 32: ...08 25211 03 2 2004 d Stoney Lane Prescot Merseyside L35 2XW...