23
INSTALLATION INSTRUCTIONS
Connect to the electricity supply
Warning:
This appliance must be
earthed.
The appliance must be installed by a
competent electrician using a double
pole control unit of
3 0
ampere minimum
capacity with 3mm minimum contact
separation at all poles.
We recommend that the appliance is
connected by a qualified electrician
who will comply with the I.E.E. and
local regulation.
1. Access to the mains terminal is
gained by opening the terminal
block cover at the rear of the
appliance (use a small flat-bladed
screwdriver).
2. Connection should be made with
6.0mm
2
twin and earth cable.
3. First strip the wires, then push the
cable through the cable clamp in
the terminal block cover.
4. Connect the cable to the terminal
block and tighten the cable clamp
screw (see diagram).
5. Close the terminal box, ensuring
that the cover is engaged on the
locking tabs.
1
2
3
4
5
Cable
clamp
Earth
(Green / Yellow
or sleeving)
Live
(Red or Brown)
Neutral
(Black or Blue)
25211 03 - Precision 1100DFa 5/8/04 11:46 AM Page 25
Содержание Heritage 1100DF
Страница 28: ...26 NOTES...
Страница 29: ...27 NOTES...
Страница 31: ......
Страница 32: ...08 25211 03 2 2004 d Stoney Lane Prescot Merseyside L35 2XW...