![Storz & Bickel GMBH VOLCANO CLASSIC Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/storz-and-bickel-gmbh/volcano-classic/volcano-classic_instructions-for-use-manual_1383065010.webp)
7.
VOLCANO DIGIT
7.1. Commissioning
Do not leave the device unat-
tended during operation. Put
the
VOLCANO DIGIT
on a flat
and stable surface.
Check whether the mains voltage cor-
responds to the voltage rating stated
on the device. The power cord and the
power plug must be in perfect condi-
tion. Only connect the
VOLCANO DIG-
IT
to a properly installed (grounded)
socket.
It is mandatory to electrically ground
the Hot Air Generator. The manufac-
turer will not bear any responsibility
whatsoever if this accident prevention
measure is not taken.
When the power plug is plugged in, the
LED display of the device lights up
briefly. At the same time, an internal
software query is performed.
The green dot on the display shows
that the Hot Air Generator is connect-
ed to the mains supply.
7.2. Heating Up
To switch on the heater, push the but-
ton labeled “HEAT”. The set/actual
temperature will light up, signaling
that the heater is switched on.
At the same time, the yellow control
lamp will light up to indicate that the
device is heating up.
The upper, red display shows the ac-
tual temperature in the Filling Cham-
ber with the air pump switched on, and
the lower, green display shows the
desired set temperature. The heat-
ing process is completed when the
set value is equal to the actual value.
The heating process can take up to 5
minutes depending upon the chosen
temperature. After the heating process
is completed, the temperature is con-
stantly maintained at the set value.
The luminous intensity of the yellow
control lamp corresponds to the inten-
sity of the heating process.
For technical reasons the
temperature in the Filling
Chamber cannot be mea-
sured during vaporization. During op-
eration the temperature is measured
at the heat exchanger. The display in-
dicates the reference values for the
attached Filling Chamber with the air
pump switched on.
Plus Temperature
Button
Minus Temperature
Button
Actual Temperature
Display (red)
Set Temperature
Display (green)
7.
VOLCANO DIGIT
When you press the plus button, the
set value is increased, and when you
press the minus button, the set value
is decreased. When you briefly tap
on the plus or minus button, the set
values are increased or decreased
respectively in 1-degree increments.
If you keep the plus or minus button
pressed, the set values start running
continuously in the corresponding
direction. If you simultaneously tap
on the plus button and the minus but-
ton, the display changes from degree
Celsius to degree Fahrenheit and vice
versa.
If the actual value is higher
than the set value, you can
speed up the cool off process
by switching on the air pump.
30 minutes after the last time
a button is pressed, the device
automatically switches off.
As long as the heater has a substan-
tial amount of residual warmth, the
temperature is displayed until it drops
be-low +40°C (+104°F). Then the dis-
play turns off, and the green dot on
the display indicates that the Hot Air
Generator is connected to the mains
supply.
7.3. Temperature Setting
18
19