background image

Minus temperature button

Plus temperature button

Actual temperature display

Set temperature display 
(displayed blinking:  
booster temperature)

Battery charging display

17 

16 

Connecting the Vaporizer using the power 
adapter or the 12 Volt car charger

7. COMMISSIONING AND OPERATION

The battery can also be 
charged via the optional 12 
Volt car charger. Connect the 

12 Volt car charger to the power sock-
et of the Vaporizer and then plug into 
the cigarette lighter or suitable 12 V 
socket. Charge and complete the op-
eration in the same way as with the 
power adapter (Chapter 7.1. “Charg-
ing the Battery”, page 15).

Batteries are specially as-
sembled consumable items 
that can only be replaced by 

Storz & Bickel when the 

MIGHTY

 Va-

porizer is sent in to them.
Any attempt by the customer to re-
place the battery by him/herself is 
potentially dangerous and leads to 
loss of any claims under the warranty 
and exempts Storz & Bickel from any 
liability.

Mains Operation 

The 

MIGHTY

 Vaporizer can also be 

operated with the power adapter, even 
when the batteries are completely 
discharged. Proceed as described in 
Chapter 7.1. “Charging the Battery”, 
page  15 and then connect up the 
Vaporizer.

Automatic Switching Off 

The automatic switching off is used to 
save battery capacity so that the Va-
porizer can be used as long as pos-
sible without charging. 
The device switches off automati-
cally two minutes after the last press 
of a button or the last application. The 
switching off of the Vaporizer is indi-
cated by a short vibration. 

A short press of the ON/OFF 
switch during operation can 
reset the automatic switching-

off to two minutes. 

7.2. Heating Up  

The 

MIGHTY

 Vaporizer provides two 

temperature levels that are set in the 
factory: The basic temperature at 
180°C (356°F) and the booster tem-
perature at 195°C (383°F).
Switch on the device (heating up the 
Vaporizer with full Filling Chamber 
and Cooling Unit mounted is recom-
mended). To do this, press the orange 
ON/OFF switch for at least half a sec-
ond. The Vaporizer responds with a 

7. COMMISSIONING AND OPERATION

short vibration. The vibration does not 
take place if there is a fault. 
The display signals that heating is in 
progress by showing the set and ac-
tual temperatures. Set the desired 
temperature using the temperature 
buttons to the left and right of the set 
temperature display. Heating up the 
heat exchanger can take up to two 
minutes, depending on the set tem-
perature and battery charge level. 

The temperature can be set between 
40°C and 210°C (104°F and 410°F) 
(see Chapter 4. “Overview of Plants”, 
page 11).
When you press the plus button, the 
set value is increased, and when you 
press the minus button, the set value 
is decreased. When you briefly tap 
on the plus or minus button, the set 
values are increased or decreased 
respectively in 1-degree increments. 

7.3. Temperature Setting 

Once the set temperature is reached, 
this is signaled by a short double vi-
bration. 
If the basic temperature can no longer 
provide adequate evaporation, the 
booster temperature can be activated 
by means of a double-click on the or-
ange-colored ON/OFF switch. Once 
the booster temperature is reached, 
this is signaled by a short double vi-
bration and a blinking Set Tempera-
ture display. 

If you keep the plus or minus button 
pressed, the set values start running 
continuously in the corresponding di-
rection. 
The booster temperature can be ad-
justed in the same way. However, it 
cannot be set lower than the previous 
set temperature.  
The current acutal temperature can be 
read from the upper line of the display. 

Содержание Mighty

Страница 1: ...STORZ BICKEL GMBH CO KG INSTRUCTIONS FOR USE Read carefully before using the device and save these instructions ...

Страница 2: ... Filling Chamber 19 8 1 Filling Aid 20 8 2 Filling the Filling Chamber Using the Filling Aid 21 9 Application 22 10 Disassembling Cleaning and Assembling 23 10 1 Disassembling and Reassembling the MIGHTY Cooling Unit 24 10 2 Cleaning the MIGHTY Cooling Unit 26 10 3 Removal of the Lower Filling Chamber Screen 26 INSTRUCTIONS FOR USE ENGLISH Table of Contents page 11 Accessories 27 11 1 Dosing Capsu...

Страница 3: ...device repairs warranty claims and disposal of the device customers in the US and Canada should contact the following address Storz Bickel America Inc 1078 60th Street Suite A Oakland CA 94608 All other customers should contact this address Storz Bickel GmbH Co KG In Grubenäcker 5 9 78532 Tuttlingen Germany 1 PRODUCT OVERVIEW MIGHTY VAPORIZER ON OFF Switch Type Label on the rear Minus Temperature ...

Страница 4: ...ance of the product with the applicable European directives and standards The device was introduced after 13 August 2005 It may not be disposed of in normal household waste The X on the trash can indicates the necessity of disposing of this device separately The device contains a built in rechargeable lithium ion battery that must be discharged before disposal Symbol for the manufacturer the manuf...

Страница 5: ...n a dry place protected against the effects of weather and out of the reach of children or unqualified persons It cannot be used in damp locations such as bathrooms etc 2 SAFETY RECOMMENDATIONS Do not operate the Vaporizer close to flammable objects such as curtains tablecloths or paper Keep the Vaporizer and power adapter away from pets e g hamsters mice and other animals which could damage the i...

Страница 6: ...inalis the leaves 190 C 374 F Thyme Thymus vulgaris the herb 190 C 374 F Below is an overview of the plants that are suitable for vaporization in the MIGHTY Vaporizer The aromas and fragrances from the plant materials listed below may be vaporized Any other use is inappropriate and po tentially dangerous It is important to observe the following instructions in order to set the MIGHTY Vaporizer wit...

Страница 7: ...ial source of dan ger Please dispose of the packing mate rial in a proper and environmentally friendly manner We recommend keeping the original packaging in case it is required later transport Storz Bickel Service Center etc 6 THE MIGHTY VAPORIZER Power Connection Before connecting up the Vaporizer make sure that the information given on the power adapter type label cor responds to the local power...

Страница 8: ...er on soft surfaces or flammable material Check whether the power adapter supply voltage cor responds to the voltage rating listed on the power adapter The power adapter cord and power adapter must be in perfect condition Connect the power adapter only to a properly in stalled socket The manufacturer will not bear any responsibility whatsoever if this acci dent prevention measure is not taken Plea...

Страница 9: ... two temperature levels that are set in the factory The basic temperature at 180 C 356 F and the booster tem perature at 195 C 383 F Switch on the device heating up the Vaporizer with full Filling Chamber and Cooling Unit mounted is recom mended To do this press the orange ON OFF switch for at least half a sec ond The Vaporizer responds with a 7 COMMISSIONING AND OPERATION short vibration The vibr...

Страница 10: ...LING CHAMBER Turn the Cooling Unit with a 90 rota tion counterclockwise in order to re move it from the Vaporizer Always fill the Filling Chamber com pletely up to the plastic rim with ground plant material Do not com Removal of Cooling Unit with Mouthpiece Filling Chamber properly filled Filling Chamber partially filled with Liquid Pad placed on top press the plant material too much so that the a...

Страница 11: ...azine for transporting and storing plant material already ground in the Herb Mill To fill the Filling Aid remove the up per cap and fill the bowl incl plug with ground plant material Replace the upper cap and close it 8 2 Filling the Filling Chamber Us ing the Filling Aid Remove the Cooling Unit from the Va porizer and remove any residues that may be in the Filling Chamber The Filling Chamber Tool...

Страница 12: ...or lung conditions Depend ing on the density the vapor could ir ritate respiratory tracts or lungs which can lead to coughing Inhale only half of air you can normally manage Hold your breath for a few seconds and exhale slowly It is advisable to delib erately concentrate on your breathing process After vaporization turn off the MIGHTY Vaporizer To do this press the orange ON OFF switch for at leas...

Страница 13: ...bel or disintegration of the glue Removal of the Cap Lock Separate the Cooling Unit Cap from the Cooling Unit Base by pulling off the cap upwards Removal of the large Base Seal Ring Remove the large and small Base Seal Rings Lever out the large Seal Ring from the recess in the notch us ing the Filling Chamber Tool Reassemble in reverse order When assembling make sure that Seal Rings are properly s...

Страница 14: ...ush cotton swabs and paper or cotton towels may be used for cleaning As solvent we rec ommend alcohol ethanol or warm water with wash up liquid For optimal airflow please ensure the Cooling Unit and Mouthpiece are clean and free from debris blockage Manual cleaning of the disassembled Cooling Unit 10 DISASSEMBLING CLEANING AND ASSEMBLING 11 ACCESSORIES 11 1 Dosing Capsules and Magazin Dosing Capsu...

Страница 15: ...y turning it clockwise Inserting the Dosing Capsules Turn the Cooling Unit with a 90 rota tion counterclockwise in order to re move it from the MIGHTY Vaporizer Removal of Cooling Unit with Mouthpiece 11 ACCESSORIES The inserted Dosing Capsule Insert the Dosing Capsule into the Filling Chamber of the MIGHTY Va porizer Then re mount the Cooling Unit by ro tating it clockwise through 90 The Filling ...

Страница 16: ...Every further use beyond this or the use of damaged and or contaminated products respectively is the user s re sponsibility We assume no liability if this recom mendation is ignored Please note that damaged or brittle Lip Pieces are not to be used Power Adapter Power consumption 36 W Supply voltage 100 240 V 50 60 Hz Output voltage 12 V DC MIGHTY Vaporizer Supply voltage 12 V DC The voltage detail...

Страница 17: ... tear Upon delivery Customer shall imme diately inspect the Products for con formity and visible defects Customer shall give Company immediate written notice of any non conformities or vis ible defects regarding the Products and contact Company in writing con cerning return or repair as the case may be Warranty Customer shall notify Company in writing of any defects of the Products Company s sole ...

Страница 18: ...such damages Company s liability for damages aris ing out of or in connection with this agreement shall in no event exceed the purchase price of the Products It is agreed and acknowledged that the provisions of this agreement allocate Repair Service After the warranty period has expired or if there are any defects which are not covered under warranty our ser vice department will repair the defect ...

Страница 19: ... GMBH CO KG In Grubenäcker 5 9 78532 Tuttlingen Germany STORZ BICKEL AMERICA INC 1078 60th St Suite A Oakland CA 94608 by STORZ BICKEL GmbH Co KG MAL 30 204 03 2017 sec_EN Subject to alterations All rights reserved ...

Отзывы: