Entering/ending ‘simplex mode’. The display will show the channel number, the
frequency and the channel spacing: 12.5, 25 or 50 KHz. (12.5 KHz is 12 on the display!)
In this mode you can directly set a frequency using
Queue
, scan by hand using
Volume
down
and
Volume up
or use automatic scan in frequency interval using
A
.
Channel spacing can be changed by the
Mode Selector
to 12.5, 25 or 50 KHz. (12.5
KHz is 12 on the display!)
#
Switch from microphone to auxiliary modulation input. On transmission the microphone
indicator will light up. The auxiliary setting has its own indicator.
When switched on, the microphone will NOT work.
Mode selector
then
#
To switch On/Off radio RX signal strength indicator (if the RSSI module is present) in the
last 2 digits of the display. Range from 00 to 99 correspond to the RSSI output level of
the module from 0 to 2 Volt. If the RSSI module is not present ‘00’ will be presented.
Tone (Call transmitter)
Switch on/off tone transmit. This key has its own indicator. Indicator on = tone activated.
Mode selector
then
tone
(Call transmitter)
To select tone frequency. The program has the 63 standard CTCSS tones + 1750 Hz
tone burst. When the RSSI module is not in place tones will only work for TX and
NOT
for
RX. Tones have to be set per channel.
How to select and set the tone frequency:
To set the tone click
Mode selector
then
Tone
. In the right part of the display the
current tone frequency will appear instead of the transmission frequency.
By repeatedly pressing the
Tone
key select the desired CTCSS or the 1750Hz tone.
CL
is back to previous.
Press
CH
to set the selected tone to the current channel. The tone will be set only
for channels stored in memory!
To unfix the tone from the channel click
CH
and then
CL
.
New tones can be set without unfixing the previous tone.
A
Swap receive and transmit frequencies (in semi-duplex channels) in
usual mode.
Start/stop automatic channel scanning at the
scan sub-mode
. In
simplex mode
at the
scan sub-mode to start/stop automatic frequency scanning from low frequency to upper
independently how they were set.
Mode selector
then
A
To switch between the two channel arrays. ‘
/
’ between frequencies = first channel array,
‘
‘ between frequencies = second channel array.
Bell
To switch Selective Call mode On/Off.
Mode selector
To expand the capacity of the keypad in combination with other keys. The
Mode
Selector
holds for 3 seconds to conveniently press other keys.
Mode selector
then
Bell
To configure the selective call mode.
Содержание CQM6113
Страница 10: ...Aansluitbox Er zijn diverse types in omloop 5...