Installation for DXPS1K30 / DXPS1W30
This unit is only suitable for installation as permanently connected equipment and the controller is
NOT SUITABLE
for
external installation
. EQUIPMENT MUST BE EARTHED
. Before installation, ensure that all power is removed from
any cabling. This equipment MUST be installed according to all relevant safety regulations. As this is permanently
connected a readily accessible disconnect device must be located near the equipment.
Fix the Controller
Install the controller to the wall following Section 1 in the FPO Manual
included with the product.
Select Input Voltage – default is 120V, cut and remove Jumper JP1 for 230V
Connect the Mains Cable to J9
J9 accepts the provided three-wire connector harness for connection to AC. Connections are by wire nut as follows:
120VAC
230VAC
Green – Earth Ground
Green – Earth Ground
Black – Hot
Black – Phase 1
White – Neutral
White – Phase 2
Keypad/Lock Wiring
Make Connections for keypad, lock and alarms into the connector blocks, then plug them into the Secure Controller
Typical setup as shown below. The black connectors are for a second keypad / second door.
Note that only keypad A can be used for programming. Leave the keypad switch in RUN mode at all times.
Ensure that you fit a spike suppressor across the door lock connections.
GREEN DOOR A KEYPAD CONNECTOR
WITH EXIT SWITCH AND DOOR SENSOR
GREEN DOOR A LOCK
CONNECTOR WITH MAG LOCK
(LINK FROM A TO C)
BLUE ALARMS CONNECTOR WITH 12V BELL
(200mA max) AND NORMALLY OPEN ALARM
SOUNDER (LINK FROM 1 TO 4)
1
KEYPAD
+12V TO KEYPAD
A
+12V
1
BELL
+12V
2
KEYPAD
KEYPAD LED/BUZZER
B
LOCK
RELAY NC
2
+12V
3
KEYPAD
KEYPAD D1
C
RELAY
COM
3
RELAY NC ALARM
4
KEYPAD
KEYPAD D0
D
RELAY
NO
4
RELAY COM
5
KEYPAD
GROUND
E
LOCK
GROUND
5
ALARM
RELAY NO ALARM
6
SENSOR
DOOR SENSOR
6
BELL
BELL
7
EXIT
EXIT SWITCH
7
GROUND
8
EXIT &
SENSOR
GROUND
8
ALARM
GROUND
CAUTION
Always connect earth ground
first
and disconnect
last