Strikemaster ES
Engineering
Manual
Strikemaster ES Engineering Manual Page 4 of 4 For more information visit
www.storm-interface.com
Rev 2 March 2015
© Copyright Storm Interface. 2014. All rights reserved
Installation for DXPS1K10 / DXPS1W10
This unit is only suitable for installation as permanently connected equipment.
The PSU is
NOT SUITABLE
for external installation
.
EQUIPMENT MUST BE EARTHED
.
Before installation, ensure that all power is removed from any cabling.
This equipment MUST be installed according to all relevant safety regulations.
As this is permanently connected a readily accessible disconnect device must
be located near the equipment.
Fix the PSU Box
Use the drill template. Mount securely allowing minimum clearance of 100mm above and side from wall.
Route mains and low voltage output cables via different cable entry holes.
Use bushes and cable glands rated to UL94 HB minimum.
Connect the Mains Cable
Use 3-core mains cable, with a minimum capacity of 3A at 240VAC. Fasten using cable ties.
Connect to the power supply terminal block
and clip the mains cable into the adjacent support clip .
Ensure the mains cable is physically secured
Keypad/Lock Wiring
The wiring diagram on the next page shows how each component must be connected.
Note that only keypad A can be used for programming
Ensure that you fit a spike suppressor across the door lock connections.
Ensure that any pairs of wires are twisted together
Mains Power Up
Apply mains power.
Check green Mains LED is on
Disconnect mains power
Standby Battery
If necessary, connect a 12V lead-acid rechargeable battery using the battery leads supplied.
Ensure the battery polarity is correct (red is +ve, black is –ve).
Please note: if the battery is partially charged, the controller might now be powered. Green LED will be on.
Apply mains power and check there is no fault indication (red LED).
After a few minutes, disconnect mains power and ensure that the controller remains powered from the battery
Controller Setup
Once you have fitted the keypad / door lock / exit switch you can configure the controller.
Press the program switch on the controller board ( LED will flash), and set a new Engineer Code.
Write down the new code inside the door of the PSU box.
Program entry codes and lock operation via the Door A connector ( either locally or from Door A keypad outside)
E
N
L
100mm
10
0m
m