The StrikeMaster ES is a robust and reliable Access Control keypad for installations requiring elevated security levels. 
Constructed to survive in exposed, outdoor or unsupervised environments these keypads combine the field proven 
durability of the StrikeMaster keypad with a remotely secured electronic control module. 
 
The control module along with a dedicated high spec power supply is contained within an alarmed, secure steel 
enclosure. This Secure Controller Unit (SCU) is located within the secured environment, protected from attempts to 
breach or disable building security systems. 
 

 

The Secure Controller Unit (SCU) supports up to two keypads and can control two doors 
 
This manual covers the entire product range, and is available from 

www.storm-interface.com/downloads

Each individual product includes a printed datasheet with just the essential information for installation.. 

Table of Contents 

 

Product Range

 

................................................................................................................................................................

 

2

 

What’s in the Box ?

 

........................................................................................................................................................

 

3

 

Installation for DXPS1K10 / DXPS1W10

 

....................................................................................................................

 

4

 

Installation for DXPS1K30 / D DXPS1W30

 

................................................................................................................

 

7

 

Programming

 

Chart

 

...........................................................................................................................................................

 

9

 

Wall

 

Fixing

 

of

 

Keypad

 

 

Fixing

 

Centres

 

Options

 

..............................................................................................................

 

11

 

Controller

 

Connections

 

 

Pictorial

 

View

 

.........................................................................................................................

 

12

 

Record

 

Card

 

.....................................................................................................................................................................

 

13

 

Controller

 

Setup

 

..............................................................................................................................................................

 

17

 

Programming Mode Functions

 

...............................................................................................................................

 

17

 

1

 

Add Entry Codes

 

............................................................................................................................................

 

18

 

2

 

Remove Entry Codes

 

....................................................................................................................................

 

18

 

3

 

Enable / Disable Tamper Mechanism on SCU Case Door

 

...................................................................

 

19

 

4

 

Change Engineer’s Code

 

.............................................................................................................................

 

19

 

5

 

Set / Change Door Strike Time

 

...................................................................................................................

 

19

 

6

 

Enable Door Sensor

 

......................................................................................................................................

 

20

 

7

 

Set Penalty Time

 

.............................................................................................................................................

 

21

 

9

 

Reset to Factory Defaults

 

............................................................................................................................

 

21

 

Example

 

System

 

Configurations

 

.....................................................................................................................................

 

22

 

 

 

Whilst every effort is made to ensure details are correct at time of print, specifications are subject to change without notice.                                           
Storm Interface products include technology protected by international patent and design registration.   Storm is a trademark of  Keymat Technology Ltd    
Storm Interface is an ISO9001 registered company.                                                              Storm Interface  is a trading name of Keymat Technology Ltd 

Содержание Strikemaster ES

Страница 1: ... is available from www storm interface com downloads Each individual product includes a printed datasheet with just the essential information for installation Table of Contents Product Range 2 What s in the Box 3 Installation for DXPS1K10 DXPS1W10 4 Installation for DXPS1K30 D DXPS1W30 7 Programming Chart 9 Wall Fixing of Keypad Fixing Centres Options 11 Controller Connections Pictorial View 12 Re...

Страница 2: ...ad incl Door A connector DXPS1W30 Strikemaster ES Controller Kit with Illuminated UL294 Keypad incl Door A connector DX1KT20 Strikemaster ES Anti Vandal Keypad incl Door B connector DX2KW20 Strikemaster ES Illuminated Keypad incl Door B connector DXPS0010 Spare Controller DXPS0030 Spare Controller UL294 RC12020 Back Box for Keypad 1KFS020 Privacy Shield for Keypad The Strikemaster ES Controller an...

Страница 3: ... 2 March 2015 Copyright Storm Interface 2014 All rights reserved What s in the Box Installation Sheet Controller both types pictured Secure Controller in UL294 PSU or Secure Controller in EU PSU Keypad Surface Box Anti Vandal and seal shown in pic Keypad Wall Screws Screws bit Plugs Leads for Battery Plugin Controller Connectors Ferrite ...

Страница 4: ...cable into the adjacent support clip Ensure the mains cable is physically secured Keypad Lock Wiring The wiring diagram on the next page shows how each component must be connected Note that only keypad A can be used for programming Ensure that you fit a spike suppressor across the door lock connections Ensure that any pairs of wires are twisted together Mains Power Up Apply mains power Check green...

Страница 5: ...ce 2014 All rights reserved PSU Connections and Fuses F1 Mains Input F2 PSU Output Fuse F3 Battery Fuse Earth Live Neutral Live Fault Battery Fuses Mains Input F1 T2AH 5mm x 20mm Time Delay Fuse Recommend Cooper Bussmann S505 2 R Output F2 F3 15A Quickblow 5mm x 20mm Recommend Cooper Bussmann S500 3 15A Battery F3 F1A Quickblow 5mm x 20mm Recommend Cooper Bussmann S500 1A ...

Страница 6: ...r construction for ease of maintenance and installation Full electronic short circuit and overload protection on load output under mains operation Mains transient protection circuit Lid opening tamper detection RATING 0 05A 24vdc Green Mains present LED Red Fault LED Input Specification Voltage rated 100 240Vac Voltage operating 90 264Vac Frequency 50 60Hz Max current 1 2A Mains Input Fuse T2 0A M...

Страница 7: ...to AC Connections are by wire nut as follows 120VAC 230VAC Green Earth Ground Green Earth Ground Black Hot Black Phase 1 White Neutral White Phase 2 Keypad Lock Wiring Make Connections for keypad lock and alarms into the connector blocks then plug them into the Secure Controller Typical setup as shown below The black connectors are for a second keypad second door Note that only keypad A can be use...

Страница 8: ...is ve black is ve Please note if the battery is partially charged the controller might now be powered Green LED 19 will be on Apply mains power Green LED will be on and check there is no fault indication on LED After a few minutes disconnect mains power and ensure that the controller remains powered from the battery Controller Setup Once you have fitted the keypad door lock exit switch you can pro...

Страница 9: ...Enter Programming Mode from Door A Keypad Press then the Engineer Code Change Engineer Code Remove code Adding a code Door Strike Time Set Penalty Time System is now in Normal Operation Mode System remains in Programming Mode A B Timed Enter Reset Factory Defaults Enter PIN length for user codes 4 5 or 6 to correspond to no of digits in code Enter or or Enable Disable Door Sensor To Enable Disable...

Страница 10: ...10 For more information visit www storm interface com Rev 2 March 2015 Copyright Storm Interface 2014 All rights reserved Drill Template for Wall Fixing of EU Controller Enclosure Use No 8 x 1 5 Panhead Screws Allow at least 100mm air space between side of case and wall ...

Страница 11: ...of Keypad Fixing Centres Options Drill the back box to suit your installation For wall fixing use the supplied screws and wallplugs Run the cable though the sealing grommet and screw the box to the wall Connect the cable to the keypad terminals Ensure the earth is connected to the rear of the keypad Write down the wire colours and test the system Fix the keypad to the back box with the security sc...

Страница 12: ...Connections Pictorial View Programming Switch with LED Door A Door B Case Tamper Connection Lock Lock from PSU Connector Connector Door A Door B Lock Lock Fuse Fuse with LED with LED Alarms Connector Door A Door B Keypad Keypad Alarms Connector Connector Fuse 12V from PSU USB Connector and Boot Swtich Fuses Use F1A Quickblow 5mm x 20mm Recommend Cooper Bussmann S500 1A Keepalive LED next to fuseho...

Страница 13: ...ENTRY CODES LIST HELD BY CHERIE Firmware Rev 2 0 NOTES DOOR A NO 10 WINE CELLAR A 12V TO LOCK RED MAGLOCK B RELAY NC BLUE C RELAY COM LINK TO 12v IF POWERED GREEN D RELAY NO E GROUND BLACK 1 12V TO KEYPAD BLUE WHITE 2 KEYPAD LED BUZZER RED WHITE 3 KEYPAD D0 GREEN WHITE 4 KEYPAD D1 ORANGE WHITE 5 GROUND YELLOW WHITE 6 DOOR SENSOR PURPLE 7 EXIT SWITCH RED 8 GROUND BLACK DOOR B A 12V TO LOCK B RELAY ...

Страница 14: ...y Codes Keep a record of which Index Positions have been used so that a entry code can be changed removed Name 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 9...

Страница 15: ...n of entry codes 4 5 or 6 digit entry code length set as an option when setting Engineer Code One or two door control Anti tamper alarm Forced door alarm Timed strike or latching door operation Timed lock out for repeated invalid code input Remote exit switch facility Fail open Fail closed option Controller Plugin connections for easy wiring identification Option for 12V or volts free operation of...

Страница 16: ...ator Under Duress Alarm The Operator Under Duress Alarm can be activated at any time by prefixing a valid entry code with the numbers 9 1 The door will open and the alarm will be activated Note if there is any possibility that this feature will be used any visible or audible alarm indicators must be located out of audible and visual range of any attacker or intruder The alarm can be cancelled by e...

Страница 17: ...quired enable the case tamper mechanism programming mode options 4 and 3 respectively Enter Entry Codes Set up entry codes and set the door strike times programming mode options 1 and 5 respectively If door sensors are fitted make sure that they are programmed to operate as desired option 6 Please note when programming mode is accessed by using the default engineer s code all programming mode func...

Страница 18: ...he entry code by pressing 1 2 3 4 5 or 6 as detailed below 1 door A timed 2 door A latched 3 door B timed 4 door B latched 5 doors A B timed 6 doors A B latched 5 Input the entry code a 4 5 or 6 digit numeric code as set up in option 4 6 To log out of programming mode press 0 or to continue programming press the required programming option number 2 Remove Entry Codes Entry codes are removed from t...

Страница 19: ...e default engineer s code of 111111 Units are shipped with this code and it can never be erased For security purposes another engineer s code should be created during initial set up The engineer s code must contain 6 digits When inputting an engineer s code in to the keypad for example to access programming mode or to turn off an alarm it must always be preceded by 1 To create the engineer s code ...

Страница 20: ...ithout a valid entry code being input i e forced entry Door entry is governed by a strike timeout and the door is left open for more than the strike timeout time even if the door was opened by using a valid entry code The alarm will stop when the door closes If the alarm is triggered because of forced entry it can be cancelled by either inputting a valid engineer s code or by entering a valid PIN ...

Страница 21: ...equired programming option number 9 Reset to Factory Defaults Selecting this option will result in the following The programmed engineer s code will erased All entry codes will be erased Entry code length will be reset to 4 digits Door strike timeout for door A and B will be reset to 5 seconds Penalty time will be reset to 15 seconds 1 To reset the SCU to its factory defaults first log into progra...

Страница 22: ...right Storm Interface 2015 All rights reserved Example System Configurations 1 Single Door Control with Mag Lock and Exit Switch 2 Two Door Control with Door Strike Exit Switch and Bell 3 Single Door Control with Mag Lock Door Sensor Connected Powered Siren for Door Open Exit Switch 4 Adding an additional keypad to an existing single door system ...

Страница 23: ...v 2 1 June 2015 Copyright Storm Interface 2015 All rights reserved CHANGE HISTORY MOST RECENT FIRST Date Details Version Updated by 9 Jun 2015 Added operator duress alarm was omitted inadvertently 2 1 JS 1 Apr 2015 Correct Bell Supply Diagram on page 7 Pin 1 is 12V Supply for Bell on Blue Conn No Change JS Pin 7 is incorrect ...

Отзывы: