P20-P23: PID parameters ("Pr.4")
Settings according to parameter group "P8-P11" for PID program "Pr.4".
P24: Switch-off delay for output relay
In the case of gas heating, switching off of the output relay is delayed by the set time. With this
setting it can be prevented that the burner is ignited in the case of short switching pulses. It must
be noted carefully that the set switch-off delay is independent of the control and overlaps it.
P25: Temperature limit for fat operating time registration
As soon the temperature is above the value set here, the fat operating time will be registered.
When the operating times set in parameters "P26" and "P27" are exceeded, a warning message
will be displayed or control will be blocked.
P26: Fat operating time until warning message
Here, you can set the time after which a warning will prompt the user to replace the used frying fat.
P27: Fat operating time until controller blocked
Here, you can set the time after which control will be blocked and the user will have to replace the
used frying fat. Once the deep fryer has cooled down, a reset can be performed in order to enable
control again and delete the registered operating time.
P28: Display of fat operating time
Here, you can view the times registered internally when the fat temperature was above the limit set
in parameter "P25". The displayed value cannot be edited, but the value can be deleted by a reset.