Temperature difference to cold store setpoint
in previous cooling
-15°C ... 0.0°C
0.0
Time limitation in previous cooling
1 ... 180 min.
10
Delay of start of defrosting after compressor
off
=2
0 ... 900 sec.
60
Dripping time
0 ... 15 min.
1
Stop delay drip tray heating
0 ... 60 min.
10
Display, forced release after defrosting
0 … 60 min. (0 = deactivated)
0
Password of parameter level
-99 ... 999
0
Fan control circuit 1
Para-
meter
Description of function
Setting range
Values
default
Fan speed control mode, Set1
0 ... 100%
80.0
Fan speed defrosting, Set1
0 ... 100%
80.0
Fan speed control mode, Set2
0 ... 100%
100
Fan speed defrosting, Set2
0 ... 100%
100
Start-up time
0 ... 60 sec.
5
Minimum speed (output variable if result=0)
0 ... 100%
10.0
Evaporator fan
Fan mode normal operation
Remark: Control setpoint if
>4
is
or
0: off
1: continuous operation
2: like 1, with drip interruption
3: with compressor on
4: temperature-controlled
evaporator sensor only
5: temperature-controlled, diff. between cold
store and evaporator sensor
3
Evaporator fan,
Fan mode defrosting
0: off
1: on
0
Evaporator fan, delay after compressor start
0 ... 600 sec.
0
Evaporator fan, Delay after defrosting
0 ... 600 sec.
120
Evaporator fan
Drip interruption time if
=2
0 ... 600 sec.
180
Evaporator fan, Control offset if
=4 or 5
-15.0 ... +15.0°C
0.0
Evaporator fan, hysteresis if
=4 or 5
0.1 ... 15.0°C
2.0
Fan speed control mode, Set1, NIGHT
0 ... 100%
90.0
Fan speed control mode, Set2, NIGHT
0 ... 100%
50.0
Assignment of condenser sensors
detailed description of sensors in parameters
through
0:none
1:Sensor F1
2:Sensor F2
3:Sensor F3
4:Sensor F4
5:weighted mean value from F1 and F2
0
Condenser fan setpoint
-55...+150°C
60.0
Condenser fan switching hysteresis
0.1...15.0°C
10.0
Condenser fan,delay after compressor start
0...300 sec.
60
Condenser fan
delay after compressor stop (after-running)
0...600 sec.
300