background image

 

Gültig seit/Valid from/Valide: 09.10.2019 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

- User Manual

 

 
 

AUTOMATIC BURNING REGULATOR 

 

SIC 700 SMART 

EN 

Содержание SIC 700 S

Страница 1: ...Gültig seit Valid from Valide 09 10 2019 User Manual AUTOMATIC BURNING REGULATOR SIC 700 SMART EN ...

Страница 2: ...et up the burning regulator 8 2 1 3 Step 3 Electrical connections 8 2 1 4 Step 4 Download and install the mobile app 9 2 1 5 Step 5 Pair the regulator with the mobile app 9 2 2 List of components and Diagram depicting the basic connection of a burning regulator 10 2 3 Connection diagram Standard connection cable for the servo 11 2 3 1 STORCH servomotor 11 2 4 Installation and assembly regulations ...

Страница 3: ...ng the stove burning without SIC 700 SMART 24 5 2 Before putting the stove into operation 27 5 3 Heating with burn off control 28 5 4 End the heating process 29 6 SAFETY INSTRUCTIONS 30 6 1 How to proceed during a power outage 30 6 1 1 Manually opening the Air flap 30 7 MAINTENANCE AND CLEANING 30 8 GENERAL PROVISIONS 30 9 TECHNICAL SPECIFICATIONS 31 ...

Страница 4: ...RCH automatic combustion regulators In order to operate with 230 V equipment the servicing person must also have the corresponding qualifications All electrical work for connection and installation must be executed in accordance with relevant valid national and regional standards and regulations and in compliance with the provisions of the local electricity supplier ...

Страница 5: ...g fireplaces or stoves is overheating Very often people add more fuel than needed This leads to a significant portion of excess energy escaping through the chimney Overheating is not economical and significantly reduces the service life of the heating system including the chimney SIC 700 SMART can detect overheating and inform the user to adjust reduce the next fuel dosage 1 3 General information ...

Страница 6: ...comfort Increases heating safety Extends the service life of the heating system Controls other external components depending on the type of regulation Indicates the need to stoke Informs about the efficiency of the heating system 1 5 Technical description of the equipment 1 5 1 Control unit Input 1x thermal unit type K t1 up to 100 C Power supply 24 V DC 1x switch to start combustion regulation o ...

Страница 7: ...meters or get access to combustion data and overheating indication We therefore recommend connecting the display panel and making use of the mobile app 1 6 Technical requirements for the mobile app 1 6 1 Android A device running Android 5 Lollipop or higher Bluetooth LE GPS Global Positioning System services The application is available for download from Google Play under the name STORCH 1 6 2 iOS...

Страница 8: ...trol unit in the plastic box o Install in an area specified by the manufacturer c Installation of the display panel LED display o install in the wood door d Installation of the door switch o The door switch automatically STARTS the burning regulator o Installation into the furnace s frame see the manual provided in the door switch packaging 2 1 2 Step 2 Set up the burning regulator Section 3 3 of ...

Страница 9: ... s location first time only Grant this permission required by the operating system in order to detect devices e The app will start searching for any nearby regulators Once a regulator is found enter the password 123456 This will pair the mobile app with the regulator Note If the application did not ask you to enter a pairing password check the notification bar of your phone For some phone types An...

Страница 10: ...10 Gültig seit Valid from Valide 09 10 2019 2 2 List of components and Diagram depicting the basic connection of a burning regulator ...

Страница 11: ...rvomotor plastic clamp 11 M4x20 screw 12 Servomotor distance washer 13 Servomotor cable 14 M4x8 screw 15 Door switch cable 16 LED display cable 17 M3x8 screw 18 3x2 washer 19 M4x6 screw 2 3 Connection diagram Standard connection cable for the servo Cable insulation up to 55 C 2 3 1 STORCH servomotor T1 thermal unit type K flue gas thermal sensor SERVO STORCH servomotor with three point control 24 ...

Страница 12: ...12 Gültig seit Valid from Valide 09 10 2019 2 4 Installation and assembly regulations 2 4 1 Temperature sensor assembly ...

Страница 13: ...13 Gültig seit Valid from Valide 09 10 2019 2 4 2 Door switch assembly ...

Страница 14: ...14 Gültig seit Valid from Valide 09 10 2019 2 4 3 Assembly of the central unit ...

Страница 15: ...15 Gültig seit Valid from Valide 09 10 2019 2 4 4 Servomotor assembly ...

Страница 16: ...16 Gültig seit Valid from Valide 09 10 2019 2 4 5 Assembly of LED display ...

Страница 17: ...important situations App colours The app uses three colours to indicate temperature in the furnace grey Standby mode green starting the fire first phase new loading yellow starting the fire second phase cooling down red burning time App colours by temperature grey green yellow red Manual restart Course of combus on stand by mode star ng the Fire burning me cooling down new loading Ac va on deac va...

Страница 18: ...aphical circular display shows the current combustion stage 1 stand by mode grey flap 0 1 2 starting the fire green yellow fl 40 100 2 3 burning time red flap 30 100 3 4 cooling down yellow flap 30 100 4 1 new loading green flap 15 Flue gas temperature The current temperature of the flue gas in the furnace Air flap position The current position of the Air flap 100 the shutter is completely open 0 ...

Страница 19: ...19 Gültig seit Valid from Valide 09 10 2019 3 2 User settings Click on the symbol to enter user settings Update see 2 1 5 Step 5 Pair the regulator with the mobile app ...

Страница 20: ... in the notification panel of your phone or tablet Notifications can be set for Requests for the next stoking Reminders to close furnace doors Combustion mode Set the combustion mode You can select between three modes ECO SMART TURBO see section 3 1 Statistics reset Reset the stoking statistics This will reset the stoking counter to zero ...

Страница 21: ...on between the app and the regulator Only do this if you want to connect the mobile device to a different regulator Service menu This is used by the authorized technicians who install the burning regulator If an untrained person makes any changes to the service menu they accept any and all responsibility arising from the potential damage caused by incorrect regulator configuration ...

Страница 22: ...22 Gültig seit Valid from Valide 09 10 2019 3 3 Service menu These settings may only be changed by a trained person A password is required to access the service menu ...

Страница 23: ...value can only be reset by resetting the device to its default factory settings Times overheated Displays how often the furnace has overheated Note this value can only be reset by resetting the device to its default factory settings Factory settings This will return the machine to its factory settings All your entered data will be deleted 4 INDICATIONS AND NOTIFICATIONS 4 1 Mobile app indications ...

Страница 24: ...he regulator s status and requests The beeper indicates Connection of the regulator to a power supply o 3x short tones New burning regulation cycle new fuel stoking the shutter will open to the 100 position o 3x short tones Furnace doors open for too long forgotten or incorrectly closed doors o 3x long tones every 3 minutes Request for fuel stoking o 1x long tone 4x short tones Transfer of regulat...

Страница 25: ...alide 09 10 2019 2 Pull out grate lever to ensure enough air coming to the chamber 3 Open the air by moving the air control lever to the right 4 During first firing in the stove leave the door slightly open 1 2 cm to avoid gluing ...

Страница 26: ...five to six loads of wood should be on higher limit of recommended amount of wood see the table in technical sheet This intensive period should last for about 5 6 hours During intensive firing door should be always closed Intensive burning makes the paint hard This process is accompanied with temporary smell which will disappear when the paint is hard During hardening process is necessary to ensur...

Страница 27: ...r 2 Check the air flap function To do this place the magnetic key 5 on the servomotor 4 see illustration Then manually check the air slide for function slide left and right 3 Pull out the grate lever rust is open air can flow unhindered into the combustion chamber 4 Slide the air slide to the left and remove the magnetic key 5 from the servomotor see illustration ...

Страница 28: ...previsous load and finishes with another load see page 18 3 At the end of the first firing process residual glow a signal sounds and the LED display flashes This means that you have to refill now you have 5 minutes to do this or burn off control switches off If you want to continue heating this is the optimal time to refuel and continue the heating process 4 Slowly open the combustion chamber door...

Страница 29: ...until the next heating process The automatic burn off control switches to standby mode gray color on stork APP and the LED indicator turns off If you open the door without firing the regulation unit will open normally but after 10 minutes will fully close again to stand by position During a power outage or if automatic regulation on the central unit is turned off or the system is disconnected from...

Страница 30: ... 7 MAINTENANCE AND CLEANING The automatic burning regulator does not require any special maintenance Do not use any aggressive cleaning agents or coarse materials that could damage the device 8 GENERAL PROVISIONS This manual is a part of the product and should be stored near the device to allow quick and easy access to information The device is not intended for use or purposes other than those des...

Страница 31: ...arts the equipment must be disconnected from the electric mains This device is not designed for use by persons incl children whose physical sensory or mental disability lack of experience or knowledge prevents them from using the equipment safely unless they are under supervision or unless they have been instructed by the person responsible for their safety in how to use the device safely Children...

Отзывы: