52
7
Assembly and setting up
Assembling machine
Adapting fluff absorption to
mains frequency
Depending on the mains frequency (50 Hz or 60 Hz), the fluff absorption
operates with or without sealing plugs.
Adapting fluff absorption
Adapting fluff absorption
The fluff absorption can be damaged if the mains
frequency is not adapted!
The fluff absorption is overloaded if it is not adapted to the
mains frequency.
-> Adapt the fluff absorption to the mains frequency.
1. Open the rear panel segments.
2. Check the sealing plugs (4) of the suction unit.
3. At Mains frequency 50 Hz: Insert sealing plug.
- or -
➜ At Mains frequency 60 Hz: Remove sealing plug.
4. Close the rear panel segments.
Connecting the knitting machine (mains voltage 400 V)