background image

4

2.2 SHIPMENT AND TRANSIT

The freezer has been assembled, operated and inspected
at the factory. Upon arrival at the final destination, the
complete freezer must be checked for any damage which
may have occurred during transit.

With the method of packaging used, the freezer should
arrive in excellent condition. THE CARRIER IS RESPON-
SIBLE FOR ALL DAMAGE IN TRANSIT, WHETHER
VISIBLE OR CONCEALED. Do not pay the freight bill until
the freezer has been checked for damage. Have the
carrier note any visible damage on the freight bill. If
concealed damage and/or shortage is found later, advise
the carrier within 10 days and request inspection. The
customer must place claim for damages and/or shortages
in shipment with the carrier. Stoelting, Inc. cannot make
any claims against the carrier.

2.3 FREEZER INSTALLATION

Installation of the freezer involves moving the freezer
close to its permanent location, removing all crating,
setting in place, assembling parts, and cleaning.

A.

Uncrate the freezer.

B.

Accurate leveling is necessary for correct drainage
of freezer barrel and to insure correct overrun.
Place a level on top of the freezer at each corner
to check for level condition. If adjustment is
necessary, level the freezer by turning the caster
in or out and tighten the locknut. (Fig 2-2).

C.

The freezer is equipped with an air cooled
condenser and requires correct ventilation. The
front of the freezer is the air intake and the back
discharge. Both front and back must have a
minimum of 3" of clearance. (Fig 2-3).

CAUTION

Failure to provide adequate ventilation will void war-
ranty.

D.

Place the OFF-ON switch in the OFF position.

E.

Connect the power cord. The plug is designed for
208 or 230 volt/20 amp duty. Check the nameplate
on your freezer for proper supply. The unit must
be connected to a properly grounded receptacle.
The electrical cord furnished as part of the freezer
has a three prong grounding type plug (Fig. 2-4).
The use of an extension cord is not recommended,
if necessary use one with a size 12 gauge or
heavier with ground wire. Do not use an adapter
to get around grounding requirement.

CAUTION

Do not alter or deform the plug in any way.

F.

Install the drip tray, drain tray, hopper cover and
other miscellaneous parts on the freezer.

Figure 2-2 Leveling

Figure 2-3 Space and Ventilation Requirements

Figure 2-4 Electrical Plug

Содержание SO212

Страница 1: ...Model SO212 OPERATORS MANUAL Manual No 513610 Rev 2...

Страница 2: ......

Страница 3: ...built prior to date of change DO NOT ATTEMPT to operate the machine until instructions and safety precautions in this manual are read completely and are thoroughly understood If problems develop or q...

Страница 4: ...ecific safety information the following safety defini tions are provided to assist the reader The purpose of safety symbols is to attract your at tention to possible dangers The safety symbols and the...

Страница 5: ...Precautions 7 3 2 Operating Controls and Indicators 7 3 3 Sanitizing 8 3 4 Freeze Down and Operation 9 3 5 MixInformation 10 3 6 Removing Mix From Freezer 10 3 7 Cleaning The Freezer 11 3 8 Disassemb...

Страница 6: ...3 SpaceandVentilationRequirements 4 2 4 Electrical Plug 4 2 5 PowerCordConnection 5 3 1 Controls 7 3 2 Mix Inlet Regulator 9 3 3 SanitizingHopper 9 3 4 DispensingProduct 10 3 5 RemovingBlender 11 3 6...

Страница 7: ...uct The freezer is designed to operate with almost any type of commercial shake mix available This manual is designed to assist qualified service personnel and operators in the installation opera tion...

Страница 8: ...LECTRICAL Description SO212 38 Voltage AC 1 PH 208 230 Total Run Amps 10 5 Drive Motor 3 4 HP Compressor 12 000 BTUH 90 F 0 F Use 20 amp HACR circuit breaker Automatic safeguard circuit built into ele...

Страница 9: ...labelshavebeendesignedtowithstand washing and cleaning All labels must remain legible for the life of the freezer Labels should be checked periodi cally to be sure they can be recognized as warning la...

Страница 10: ...and to insure correct overrun Place a level on top of the freezer at each corner to check for level condition If adjustment is necessary level the freezer by turning the caster in or out and tighten t...

Страница 11: ...of electrical supply before servicing A Remove the left side panel and electrical box cover B Disconnect the wires from the terminal block Disconnect the green ground wire from the grounding stud Fig...

Страница 12: ...6...

Страница 13: ...main electrical power has been disconnected SECTION 3 INITIAL SETUP AND OPERATION G Donotoperateunderunsafeoperatingconditions Never operate the freezer if unusual or excessive noise or vibration occ...

Страница 14: ...attheproduct has reached the proper temperature and is ready to be dispensed NOTE If the red light next to the PUSH TO FREEZE but ton is illuminated press the PUSH TO FREEZE but ton and wait until the...

Страница 15: ...acturer sinstructions Setasidea large cup of sanitizer solution to sanitize the blender Pour the remainder of the solution into hopper C PlacethePowerOFF ONswitchintheONposition and press the CLEAN bu...

Страница 16: ...g J Thefreezerisdesignedtodispensetheproductat areasonabledrawrate Ifthefreezerisoverdrawn the result is a very thin product If this should occur allow the freezer to run for approximately 30secondsbe...

Страница 17: ...fter the mix has been removed from the freezer the freezer must be cleaned To clean the freezer refer to the following steps A Close the spigot and fill the hopper with 2 gallons 7 5 liters of tap wat...

Страница 18: ...s refer to the following steps A Place all parts in warm mild detergent water and clean with brushes provided Rinse all parts with clean hot water NOTE If a dishwasher is used product damage is likely...

Страница 19: ...t door on the freezer I Install the blender assembly onto the front door studsandtightenthecircularknobsonthefreezer studs CAUTION Overtightening or uneven tensioning of circular knobs may cause damag...

Страница 20: ...is disassembled and removable parts are taken to the sink for cleaning 2 MILKSTONE REMOVAL Since almost all cleaners do not have the ability to remove milkstone the use of a delimer becomes necessary...

Страница 21: ...to disengagefromthesupportandpullingout Clean behind the drip tray and front of the freezer with a soap solution C MONTHLY CAUTION The freezer has an air cooled condenser and must have the proper air...

Страница 22: ...16...

Страница 23: ...t space for free flow of cooling air 2 A minimum of 3 of vent space required 3 Air temperature entering condenser is above 100 F 3 Change location or direct hot air away from freezer 4 Condenser is di...

Страница 24: ...o rings 3 Replace o rings 4 O rings or spigot installed wrong 4 Remove spigot and check o ring 5 Inner spigot hole in front door nicked or scratched 5 Replace front door 1 EPR valve needs adjustment...

Страница 25: ...Decal Attention Refrigerant Leak Check 324393 Decal Stoelting Swirl Logo Drip Tray Support 324509 Decal Cleaning Instructions 324566 Decal Wired According To 324584 Decal Adequate Ventilation 3 1 324...

Страница 26: ...0 SV Door w Pins 1 624614 5 O Ring Spigot Black 5 Pack 2 624678 5 O Ring Rear Seal Black 5 Pack 1 625314 O Ring Front Door Black 1 666786 Seal Rear Auger Black 1 2183751 Blade Scraper Ser 28938 Plus 1...

Страница 27: ...09 Grid Drip Tray White Honeycomb 1 521026 Blender Agitator 1 624607 5 O Ring Mix Inlet Black 5 Pack 2 674174 Blender Shaft 1 681518 Shield Plastic Swing 1 744266 Tray Drip White 1 1177740 Mix Inlet A...

Страница 28: ...22...

Страница 29: ...se obligations remedies are subject to the conditions that Buyer a signs and returns to Stoelting upon installation the Start Up and Training Checklist for the affected equipment b gives Stoelting pro...

Страница 30: ...ed to hoses piping or electrical equipment e Labor and travel charges due to return trips or waiting if the Authorized Stoelting Provider is prevented from promptly starting service work upon arrival...