Error Code 5 - Freezing Cylinder Sensor
The Freezing Cylinder Sensor Error (E5) indicates
a failure of the barrel sensor or an extreme out of
range condition (< -34°F or > 99°F). If the control
panel displays an E5, place the Freezing Cylinder
Off-On switch Off and back On. If the error persists,
contact your Authorized Stoelting Distributor for
further assistance.
NOTE
When the machine encounters a Freezing Cylinder
Sensor Error, the machine will continue to run using
preset timers. This mode will allow the operator to
continue serving product until the machine can be
serviced.
Error Code 6 - Hopper Sensor (single hopper machines)
The Hopper Sensor Error (E6) will not occur on the
machine.
Error Code 7 - Drive Motor
If the control panel displays a Drive Motor Error
(E7), the control does not sense current coming
from the drive motor. Turn the Freezing Cylinder
Off-On switch Off and back On. If the error persists,
contact your Authorized Stoelting Distributor for
further assistance.
Error Code 8 - Cab Sensor
A Cab Sensor Error (E8) will not occur on the
machine.
Error Code 9 - High Pressure Cutout
High Pressure Cutout Errors (E9) are usually
caused by a dirty or inefficient condenser. If the
control panel displays an E9 on an air cooled
machine, check for proper air clearance around the
machine. If the error persists, contact your
Authorized Stoelting Distributor for further
assistance.
Error Code 10 - Auxiliary Sensor
An Auxiliary Temperature Sensor Error (R10)
occurs if the temperature sensor on the control
board fails. Turn the Freezing Cylinder Off-On
switch Off and back On. If the error persists,
contact your Authorized Stoelting Distributor for
further assistance
Error Code 11 - Low Temperature
The Low Temperature Error (E11) occurs when the
temperature of the gas refrigerant at the barrel
sensor falls below -20°F. Although the machine
will not shut down, the active freezing cycle will
immediately end. This error usually occurs when
the machine continues to run in a low mix condition
or if the machine runs out of mix. The product
towards the front of the barrel tends to freeze solid.
Error Code 12 - Left Hopper Sensor
The Left Hopper Sensor Error (E12) indicates a
failure of the hopper sensor or an extreme out of
range condition (< -34°F or > 99°F). If the control
panel displays an E12, turn the left Freezing
Cylinder Off-On switch Off and back On. If the error
persists, contact your Authorized Stoelting
Distributor for further assistance.
NOTE:
If the right control panel shows an E12, make sure
the storage setting is set to NONE.
Error Code 13 - Right Hopper Sensor
The Right Hopper Sensor Error (E13) indicates a
failure of the hopper sensor or an extreme out of
range condition (< -34°F or > 99°F). If the control
panel displays an E13, turn the right Freezing
Cylinder Off-On switch Off and back On. If the error
persists, contact your Authorized Stoelting
Distributor for further assistance.
NOTE:
If the right control panel shows an E13, make sure
the storage setting is set to NONE.
Alternating Flashing Control Panel Lights
The display panel lights will flash in an alternating
sequence under any error codes. Clear the error
and place the Freezing Cylinder Off-On switch in
the Off position and back in the On position.