13
F112 Air Cooled Condenser Cleaning
A.
Remove the Phillips head screws from the bottom
of the left side panel, and then slide the panel down
and out.
B.
To remove the condenser filter, grasp the top and
pull off. Visually inspect for dirt. If the filter is dirty,
shake or brush excess dirt off the filter and wash in
warm, soapy water. Once the filter is clean rinse
thoroughly in warm, clear water and shake dry,
taking care not to damage the filter in any way (Fig.
3-8).
C.
Visually inspect the condenser for dirt by shining
a light through the coil from the back (inside) of the
condenser.
D.
If the condenser is dirty, place a wet towel over the
front (outside) of the condenser.
E.
Using a vacuum, carefully clean the condenser coil
from the inside and outside of the machine. A stiff
bristled brush may help in releasing debris from
between the condenser coils.
Water Cooled (F112 only)
The water-cooled condenser is a tube and shell type. The
condenser needs a cool, clean supply of water to properly
cool the machine, inlet and discharge lines must be 3/8” I.D.
minimum. Make sure the machine is receiving an unre-
stricted supply of cold, clean water.
E.
SEMI-ANNUALLY
1.
Disconnect the machine from the power source.
2.
Check drive belt for proper tension. Push belt in
with one finger, belt should deflect about 3/8".
3.
Lubricate condenser fan motor with S.A.E. 20
weight oil. Three to six drops are required.
4.
Sanitize the autofill system following the steps
below:
AUTO FILL SANITIZING
A.
If necessary, disassemble, clean and sanitize the
machine.
NOTE
If the machine does not require cleaning and sani-
tizing, turn it off and dispense enough product so
that the mix level in the hopper is below the long
probe. If the mix level is above the long probe, the
solenoid will not activate and the pump will not oper-
ate.
B.
Prepare Stera-Sheen Green Label Sanitizer
according to manufacturer’s instructions to provide
a 100ppm strength solution. In the blue cleaner/
sanitizer bucket, mix 1 packet of sanitizer and 2
gallons of cold water. Check the chlorine content
with a test strip to ensure 100ppm strength.
C.
Cut an adapter from an empty bag of syrup.
Connect the adapter to the BIB connector of the
syrup line. Put the BIB connector into the bucket
of sanitizer.
NOTE
If you do not have an emtpy bag of syrup, remove
the plug from the top of the BIB connector. Do not
lose the plug; it is needed for proper operation of the
BIB.
D.
Hold the hopper cover over a bucket and set the
machine to clean. The solenoid will activate and
the brix pump will pump sanitizer into the bucket.
NOTE
The solenoid will only activate when there is not any
liquid touching the longer mix probe in the hopper.
E.
After all the sanitizer has run through the pump,
turn the machine off.
F.
Disconnect the bag adapter from the BIB connector
(or reinsert the plug into the connector). Connect
the BIB connector to the syrup BIB.
G.
Set the machine to clean and hold the hopper cover
over a bucket. This will flush the sanitizer out of the
pump and tubing. When pure syrup comes out of
the tubing, turn the machine off.
H.
The machineis now ready to operate. Place the
hopper cover on the hopper and turn the machine
on.
Figure 3-8 F112 Condenser Filter Removal