![Stoelting E112-LJ Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/stoelting/e112-lj/e112-lj_operators-manual_1381568015.webp)
9
A.
Pull out the spigot pin by its ring. Remove the
spigot handle.
NOTE
Place all parts into the lemonade parts basket im-
mediately after removing from the machine. Place
small parts onto the small parts rod in the basket.
B.
Remove front door by turning the circular knobs
and then pulling door off the studs.
NOTE
When removing front door, entire door and stator
assembly will come out as well.
C.
Remove the torque rod from the stator assembly.
D.
Remove the quad ring from the groove in front door.
E.
Remove the stator bar. Remove the small white
bushing.
F.
Remove the o-rings at the front and back of the
stator bar by first wiping off the lubricant using a
clean paper towel. Then squeeze the o-ring upward
with a dry cloth. When a loop is formed, roll the o-
ring out of the groove.
G.
Remove the auger support bushing.
H.
Turn the spigot body until the ice breaker bar can
be removed. Remove breaker bar.
I.
Remove the spigot body from the front door.
J.
Remove the o-rings (2) from the spigot.
K.
Remove the auger assembly from the freezing
cylinder and remove the auger blade. Remove the
rear seal and o-ring from the auger.
L.
Remove the drain tray, drip tray and drip tray grid.
M.
Remove the hopper cover and disconnect the auto
fill adapter from the cover by pulling out the retaining
clip.
3.5 CLEANING AND SANITIZING THE
MACHINE PARTS
Place all loose parts in a pan or container and take to the
wash sink for cleaning. Local and state health codes dictate
the procedure required. Some health codes require a four-
sink process (pre-wash, wash, rinse, sanitize, and air-dry),
while other codes require a three-sink process (without the
pre-wash step). The following procedures are a general
guideline only. Consult your local and state health codes for
procedures required in your location.
A.
Set up a 3-compartment sink with wash, rinse and
sanitize compartments. Use only Stera Sheen
Green Label or Kay-5 Green. Prepare sanitizer
according to manufacturer’s instructions to provide
a 100ppm strength solution. Set aside a small
amount of sanitizer
B.
Clean all parts using brushes provided.
C.
After cleaning, remove the parts and let air dry.
Figure 3-4 Removing O-Ring
Figure 3-3 Spigot and Ice Breaker Bar Removal
Figure 3-2 Remove Spigot Pin
Содержание E112-LJ
Страница 1: ...Model E112 LJ F112 LJ OPERATORS MANUAL Manual No 513643 Feb 2010...
Страница 2: ......
Страница 6: ......
Страница 8: ...2 Figure 1 2 Specifications E112 F112 1 2 SPECIFICATIONS...
Страница 10: ...4...
Страница 28: ...22...