background image

Operators Manual #513852 Rev.2 

CBD Model Machines

SECTION 3

INITIAL SET-UP AND OPERATION

3.1 OPERATOR’S SAFETY PRECAUTIONS 

SAFE OPERATION IS NO ACCIDENT; observe these 
rules:

A. 

Know the machine. Read and understand the 
Operating Instructions.

B. 

Notice all warning labels on the machine.

C. 

Wear proper shoes and clothing. Avoid loose 
fi tting garments, and remove watches, rings or 
jewelry that could cause a serious accident. Do 
not operate with wet hands or feet.

D. 

Do not allow children to use the machine.

E. 

Maintain a clean work area. Avoid accidents by 
cleaning up the area and keeping it clean.

F. 

Stay alert at all times. Know which switch, push 
button or control you are about to use and what 
effect it is going to have.

G. 

Disconnect electrical cord for maintenance. Never 
attempt to repair or perform maintenance on the 
machine until the main electrical power has been 
disconnected. Unplug the machine at the plug. 
Do not pull the electrical cord to disconnect the 
machine from the power source.

H. 

Do not operate under unsafe operating conditions. 
Never operate the machine if unusual or excessive 
noise or vibration occurs.

3.2 OPERATING CONTROLS AND INDICATORS 

Before operating the machine, it is required that the op-
erator know the function of each operating control. Refer 
to Figure 3-1 for the location of the operating controls on 
the machine.

A. 

Main Power Switch

 

The Main Power Switch controls the operation of 
the refrigeration system and the augers. In the 
Off position, power is not supplied to the control 
board, refrigeration system or augers. Place it in 
the On position for normal operation.

Figure 3-1 Controls

Main Power 

Switch

Spigot 

Lock

WARNING

High voltage will shock, burn or cause death. The 
Main Power switch must be placed in the Off posi-
tion prior to disassembling for cleaning or servicing. 
Do not operate machine with the panels removed.

Содержание CBD117

Страница 1: ...Model CBD OPERATORS MANUAL Manual No 513852 Rev 2...

Страница 2: ......

Страница 3: ...PT to operate the machine until instructions and safety precautions in this manual are read completely and are thoroughly understood If problems develop or questions arise in connection with installat...

Страница 4: ...ecific safety information the following safety defini tions are provided to assist the reader The purpose of safety symbols is to attract your at tention to possible dangers The safety symbols and the...

Страница 5: ...ator s Safety Precautions 7 3 2 Operating Controls and Indicators 7 3 3 Assembly of Machine 8 3 4 Sanitizing 9 3 5 Freeze Down and Operation 9 3 6 Removing Mix From Machine 10 3 7 Disassembly of Machi...

Страница 6: ......

Страница 7: ...ols to provide a uniform product They operate with almost any type of frozen beverage mix This manual is designed to help qualified service personnel and opera tors with the installation operation and...

Страница 8: ...6 cm Weight 55 lbs 24 9 kg 75 lbs 34 0 kg Electrical 1 Phase 115 VAC 60Hz 1 Phase 115 VAC 60Hz running amps 5 5A 12A connection type NEMA5 15P included NEMA5 15P included Compressor 426 Btu hr 608 Btu...

Страница 9: ...on of the machine involves moving the machine close to its permanent location removing all crating set ting in place assembling parts and cleaning A Uncrate the machine B Remove the packing material a...

Страница 10: ...our Button changes the hour when setting the time or programming a defrost setting Minute Button The Minute Button changes the minute when setting the time or programming a defrost setting Bypass Butt...

Страница 11: ...Press the h and m button to set the time D Press the P button to save the setting E The display shows a 2 which signifies when the machine returns to normal operation Follow steps B C and D above to p...

Страница 12: ...Operators Manual 513852 Rev 2 6 CBD Model Machines...

Страница 13: ...ne until the main electrical power has been disconnected Unplug the machine at the plug Do not pull the electrical cord to disconnect the machine from the power source H Donotoperateunderunsafeoperati...

Страница 14: ...ogrammed for defrost mode at specific intervals The timer is located behind the right panel To program the timer refer to Section 2 4 D Spigot Lock The Spigot Lock is a lever located behind the spigot...

Страница 15: ...es Any sanitizer must be used only in accordance with the manufacturer s instructions In general sanitizing may be conducted as follows A Prepare Stera Sheen Green Label Sanitizer or equivalent accord...

Страница 16: ...uency of cleaning the machine and ma chine parts must comply with local health regula tions After the mix has been removed from the machine follow the steps below to disassemble the parts A Remove the...

Страница 17: ...on 3 9 ROUTINE CLEANING To remove spilled or dried mix from the machine exterior wash in the direction of the finish with warm soapy water and wipe dry Do not use highly abrasive materials as they mar...

Страница 18: ...Operators Manual 513852 Rev 2 12 CBD Model Machines...

Страница 19: ...tes Once the calibration is completed normal operation continues COLD DRINK MODE LED BLINKING This indicates that the defrost mode is active Refer to Section 2 4 for details on the defrost mode SLUSH...

Страница 20: ...Operators Manual 513852 Rev 2 14 CBD Model Machines...

Страница 21: ...TION 5 REPLACEMENT PARTS Part Description Quantity 324987 Decal Pull Here 1 per tank 5 1 DECALS Part Description Quantity 493128 Cover Tank 1 per tank 396697 Gasket Tank 1 per tank 724058 Tank 1 5 Gal...

Страница 22: ...ontal Auger 1 per tank 428096 Handle Assembly 1 per tank 442128 Lever Tank Clamp 2 per tank 442129 Hook Tank Clamp 2 per tank 538620 Fastening Nut Vertical Auger 1 per tank 538621 Auger Service Knob 1...

Страница 23: ...onent from into the equipment Those obligations remedies are subject to the conditions that Buyer a signs and returns to Stoelting upon installation the Start Up and Training Checklist for the affecte...

Отзывы: