Monitoring and diagnosis on the inverter
Operation manual
ID 441896.05
WE KEEP THINGS MOVING
61
10
A263.0 EtherCAT Sync Manager 1 Synchronization type
The parameter indicates the synchronization operating mode for Sync Manager
1 (read mailbox) which was set by the controller on the inverter. Since Sync
Managers for mailbox communication are never synchronized, the parameter
can only have the following values:
0: not synchronized
No other values possible.
Information
Please note that the synchronization operating mode is set exclusively by the
controller. If you change the parameter, your settings will have no effect.
Axis:
Global
Data type:
U16
Value:
0: Not synchronized;
1: Synchronized with AL event on this Sync Manager;
2: Synchronized with AL event Sync0;
3: Synchronized with AL event Sync1;
32: Synchronized with AL event of SM0;
33: Synchronized with AL event of SM1;
34: Synchronized with AL event of SM2;
35: Synchronized with AL event of SM3;
Index:
2107
hex
Subindex:
0
hex
A263.1 EtherCAT Sync Manager 1 Cycle time
The parameter indicates the value of the cycle time for Sync Manager 1 (read
mailbox) which was set by the controller on the inverter. Since Sync Managers
for mailbox communication are never synchronized, the parameter can only
have the following values:
0: not synchronized
No other values possible.
Information
Please note that the cycle time is set exclusively by the controller. If you change
the parameter, your settings will have no effect.
Axis:
Global
Data type:
U32