10
Monitoring and diagnosis on the inverter
ID 441896.05
WE KEEP THINGS MOVING
Operation manual
60
Value:
0: Not synchronized;
1: Synchronized with AL event on this Sync Manager;
2: Synchronized with AL event Sync0;
3: Synchronized with AL event Sync1;
32: Synchronized with AL event of SM0;
33: Synchronized with AL event of SM1;
34: Synchronized with AL event of SM2;
35: Synchronized with AL event of SM3;
Index:
2106
hex
Subindex:
1
hex
A262.2 EtherCAT Sync Manager 0 Shift time
The parameter indicates the value of the shift time for Sync Manager 0 (write
mailbox) which was set by the controller on the inverter. Since Sync Managers
for mailbox communication are never synchronized, the parameter can only
have the following values:
0: not synchronized
No other values possible.
Information
Please note that the shift time is set exclusively by the controller. If you change
the parameter, your settings will have no effect.
Axis:
Global
Data type:
U32
Value:
0: Not synchronized;
1: Synchronized with AL event on this Sync Manager;
2: Synchronized with AL event Sync0;
3: Synchronized with AL event Sync1;
32: Synchronized with AL event of SM0;
33: Synchronized with AL event of SM1;
34: Synchronized with AL event of SM2;
35: Synchronized with AL event of SM3;
Index:
2106
hex
Subindex:
2
hex