![Stober AX 5000 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/stober/ax-5000/ax-5000_operating-manual_1381284016.webp)
Terminal Overview
ID 441689.03
16
Operating manual Axis switch POSISwitch® AX 5000
6
WE KEEP THINGS MOVING
Terminal description X501 – voltage supply and relays
LED
Pin
Designation
Function
Data
+24 V
DC
Voltage supply
—
0 V
Reference for 24 V
—
PE
Protective conductor
—
K+
Power for the relays
+ Potential for powering power
relays/contactors
U
min
= 5 V
U
max
= 30 V
K-
Reference potential for Pin 4
—
K1 OUT
Relay output for 1
st
axis
I
max
(24 V) = 0.2 A,
Internal safety circuit with free-
wheeling diode for relay coil.
K2 OUT
Relay output for 2
nd
axis
K3 OUT
Relay output for 3
rd
axis
K4 OUT
Relay output for 4
th
axis
Designation
Meaning
ON
When the LED is on, the axis switch is supplied with
voltage.
1
When the LED is on, axis 1 is selected.
a)
a) When the LED is on, communication is taking place with the encoder of the axis. The
relay output (X501.K1 OUT to X501.K4 OUT) becomes active when the axis is activated
by axis management (device control).
2
When the LED is on, axis 2 is selected.
a)
3
When the LED is on, axis 3 is selected.
a)
4
When the LED is on, axis 4 is selected.
a)