Electrical installation
This chapter gives you complete information on the subject of electrical installation. Only specialized
personnel qualified for this task may install, commission and control the device.
5.1
EMC Connection
•
Mount device on conductive surface (unpainted).
•
Install motor cable and encoder cable separately from each other.
•
Use only shielded cables for motor and encoder lines (corresponding cabels can be ordered from
STÖBER ANTRIEBSTECHNIK).
•
Apply shield of the motor cable on both sides.
•
The circuit breakers may not interrupt the shield lines.
•
Use output derating for motor lines > 50 m.
•
When an additional transmission plug connector is installed in the motor cable, the shield may not be
interrupted and the plug connection may not be opened when the motor is electrified.
•
When the braking line is installed in the motor cable, the braking line must be shielded separately.
5.2
Connecting
5.2.1
POSISwitch® AX 5000 to MDS 5000/SDS 5000
POSISwitch® AX 5000 is controlled by POSIDRIVE® MDS 5000 or by POSIDYN® SDS 5000. A connection
via socket X4 on the inverter to plug X500 on the AX 5000 enables the switching of the axes. Completely
prefabricated cables are available in the lengths 500 mm (ID no. 45405) and 2500 mm (ID no. 45386). Cf.
chap. 9 Accessories). POSISwitch® AX 5000 is usually installed in the immediate vicinity of the inverter (see
chap. 3.1 Electrical Data and chap. 3.2 Mechanical Data). However, if this is not possible or desirable, a cable
of up to 80 m
1
in length can be used.
5.2.2
POSISwitch® AX 5000 to Encoder
The encoders of the individual servo motors are connected to POSISwitch® AX 5000 with the STÖBER
encoder cable. The encoder of the first motor is connected with the socket Enc. 1.The encoder of the second
motor is connected with the socket Enc. 2 and so on.
The length of the encoder cable may not exceed 20 m
2
.
Information
This chapter gives you general information on EMC-suitable
installation. These are only recommendations. Depending on the
application, the ambient conditions and the legal requirements,
measures in addition to the following recommendations may be
necessary.
1
Only valid in connection with STÖBER cables.