Electrical Supply
Installation must be carried out by a qualified electrician in
accordance with BS 7671:2008 Wiring Regulations.
230/240V AC 50/60Hz mains supply to a suitable SELV
LED Driver.
Site conditions: LED equipment is more susceptible to
static damage and overvoltage than previous technology.
Before handling or connecting to the mains supply ensure
that all MSL products are protected from static discharge
and that the mains supply is to regulation. (230V +10
-6%)
This fitting is supplied with a Xicato LED module. Refer to
the fitting label for the module version and wattage. More
information on the module can be found at
www.xicato.com/support
Mains cables must be double insulated, strain relieved
and separated from E.L.V output cables.
If using the Xicato XTM Module;
This unit requires a constant current driver. 700mA Max.
If using the Xicato XIM Module;
This unit requires a 48V constant voltage driver.
Observe polarity:
Positive (+) is marked as RED.
Incorrect supply or reverse polarity can cause irreparable
damage.
All connections must be made before switching on mains.
If the supply is energised prior to making the connections
to the fitting then the resulting surge will damage the LED.
All lighting equipment is delicate and easily damaged
through misuse or inappropriate installation (mechanical
or electrical). Repairs and replacements may cause
delays and will be chargeable. Contact MSL for support if
required. For full warranty terms & conditions please visit
our website.
The light source contained in this luminaire shall only be
replaced by the manufacturer or his service agent or a
similar qualified person.
The entire dimming control circuit source must be of
SELV insulation class.
Installation
Check that the mounting surface is suitable for the
installation of this fitting.
A 92mm diameter hole is required for mounting.
Step 1 Make mains connections to SELV LED driver
and extra low voltage connections to the
fitting.
Step 2 Insert the fitting into the cut-out.
Step 3 Tightening the 2 CSK fixings will swing the
ceiling tabs out and secure the fitting in place.
Step 4 Fit the coverplate.
Ensure that the installation of this fitting does not
compromise any fire barrier offered by your ceiling.
Intumescent downlighter fire hoods should be used to
maintain the integrity of the barrier in the event of a
fire.
Do not cover the luminaire with insulation. Heat sinks
and fan assisted lamps must be kept free from dust
and well ventilated to ensure long term reliability and
light quality.
WARNING: Do not look at exposed LED lamps in
operation. Eye injury can result.
Cleaning:
Fully isolate the fitting and allow to cool.
Clean the fitting with a slightly damp lint free cloth
from a mild solution of soap and water. The fitting
must be completely dry before reconnecting power.
Incompatible or abrasive chemicals can damage the
fitting, contact MSL for advice if required.