22
AFTER SALES SUPPORT
1300 886 649
AUS
MODEL: STR-SGC60 PRODUCT CODE: 700793 04/2020
Installation (Cont.)
Adjusting the minimum level of the flame
IMPORTANT:
Before adjusting the minimum level of the flame, make sure
all gas is switched off (and preferably disconnected from the appliance)
and the electrical power has been disconnected.
1. Turn the tabs down to minimum.
2. Remove the knob from the tap (Fig. 13) and place a small-bladed
screwdriver in the centre of the tap shaft.
3. The correct adjustment is obtained
when the flame has a length
of about 3–4 mm. (For butane/
propane gas, the adjustment screw
must be tightly screwed in.)
4. Refit the caps, flame spreaders
and knobs after finishing the
adjustment.
5. Make sure that the flame does not
go out by quickly turning the knob
from maximum flow to minimum
flow. If the flame goes out, then
remove the control knob and
make further adjustments to the
gas flow, testing it again once the
adjustment has been made.
6. Repeat this process for each one
of the gas taps.
Fig. 13
CAUTION!
• Do not dismantle the tap shaft. In the event of a malfunction, change the
whole tap.
• When replacing the flame spreaders and burner caps, make sure that the
injector is not blocked.
• A full operational test and a test for possible leakages must be carried out
after gas conversion; see page 23 for details.