Clearances
The clearances listed below are required when installing the appliance
into a
kitchen unit (depending on size) or 600mm worktop (Fig. 1):
• The edges of the cooktop must be a minimum distance of
60mm
from a
side or rear wall.
• The highest point of the cooktop surface (including the burners and trivets)
must be a minimum distance of:
–
700mm
to the underside of any horizontal surface directly above it
–
400mm
to the underside of any horizontal surface if it is in line with the
outer edge of the cooktop (if the underside of the horizontal
surface is lower than 400mm, then it must be
at least 50mm
away from the outer edges of the cooktop)
• There must be a
50mm
clearance around the appliance and between the
cooktop surface and any combustible materials.
• Fire resistant materials
(such as ceramic tiles) are required up to
450mm
above the burner top.
• If installing above an oven, the oven must have forced ventilation. Check
the necessary clearances and cut-out requirements in the oven installation
manual.
Installation (Cont.)
Clearances required when fitting the
cooktop with a rangehood above
Rangehood
400mm
700mm
600mm
553mm
200mm
min.
60mm
473mm
400mm