background image

State:  16.06.2021 p. 2

 

Mounting instructions for „Calisthenics“ robinia  

Item-No. 55 1520 602

©  stilum GmbH, Gewerbegebiet Larsheck, D-56271 Kleinmaischeid  •  Tel. +49 (0) 2689 92790-0  •  All rights and product modifications reserved.     

health

1. 

Select the fitness equipment location in consideration of the required move

-

ment area (see diagram 4).

2. 

Select the postition of the instruction sheet. 

 

Attention: 

Because of the risk of injury, the instruction sheet has to be arran

-

ged outside of the movement area.

3. 

Carry out excavation work for the foundations as shown in diagram 2. 

 

After excavation compress the foundation floor. 

 

Note: 

Pay attention to items marked „ground level“ at the equipment! 

4.  Carry out excavation work for the instruction sheet foundations as shown in 

diagram 5. After excavation compress the foundation floor. 

5.  Set up the concrete foundations according to diagram 2 and 5 with central, 

horizontal reinforcement. 

6. 

After a setting period of 10 – 14 days, depending on weather conditions and 
foundation size, fill up and compress the holes between the foundation and 
the foundation hole with excavation. Clean the foundation surface.

7. 

Screw the four posts with the pull-up module to the clamps (diagram 3c). Pay 
attention to the exact installation according to diagram 1, 2 and 3d.

 

Note: 

Do not screw the base plates onto the foundations yet!

Diagram 2: Foundation plan

Reinforcement plan: 

Concrete foundation with reinforcement

Foundation: BSt 500S

 

Stirrups Ø 8 mm lengthwise and cross

 

Concrete cover h´= 3 cm
Concrete quality class C20/25

ground level

4484

400

 450 

 2234 

 1309 

 2368 

 2512 

750

1191

600

866

600

750

1300

50

1200

200

1150

87

1800

600

1387

2050

5237

600

1340

600

1825

600

100

 1259 

 954 

 234 

 4965 

 806 

 600 

OHNE SCHRIFTLICHE ZUSTIMMUNG DER KAISER GMBH DARF DIESE 

TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT, NOCH DRITTEN MITGETEILT ODER 

ZUGÄNGLICH GEMACHT WERDEN, NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER- 

WENDET WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.

1

 

calisthenics Robinie 450

Benennung

Gepr.

Blatt

Datum

Projekt

Gez.

Zeichnungsnummer

1:50

A3

Name

Name

Fundament

2019-00-00

Maßstab

Schramm

03.05.17

 

 

Gewerbegebiet Larsheck

56271 Kleinmaischeid

Deutschland

Beton

concrete

gewachsenes Erdreich

natural ground

Legende

stoßdämpfender Boden

shock-absorbing floor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B stoßdämpfender Boden

20.01.21 ES

ES

26.02.18

Abstandsmaß

A

Datum

Änderung

Rev

4485

400

 2234 

 150 

 2542 

 2369 

 1309 

750

1191

600

866

600

750

1300

50

1200

200

1150

87

1800

600

1387

2050

5237

600

1340

600

1825

600

100

 4965 

 806 

 600 

OHNE SCHRIFTLICHE ZUSTIMMUNG DER KAISER GMBH DARF DIESE 

TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT, NOCH DRITTEN MITGETEILT ODER 

ZUGÄNGLICH GEMACHT WERDEN, NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER- 

WENDET WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.

1

 

calisthenics Robinie 150

Benennung

Gepr.

Blatt

Datum

Projekt

Gez.

Zeichnungsnummer

1:50

A3

Name

Name

Fundament

2006-00-00

Maßstab

Schramm

03.05.17

 

 

Gewerbegebiet Larsheck

56271 Kleinmaischeid

Deutschland

Beton

concrete

gewachsenes Erdreich

natural ground

Legende

stoßdämpfender Boden

shock-absorbing floor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B stoßdämpfender Boden

20.01.21 ES

ES

26.02.18

Abstandsmaß

A

Datum

Änderung

Rev

Содержание Calisthenics 55 1520 602

Страница 1: ...m No 55 1520 602 stilum GmbH Gewerbegebiet Larsheck D 56271 Kleinmaischeid Tel 49 0 2689 92790 0 All rights and product modifications reserved health Diagram 1 Overall view of the fitness equipment dip module push up module climbing module leg workout module pull up module ...

Страница 2: ...odule to the clamps diagram 3c Pay attention to the exact installation according to diagram 1 2 and 3d Note Do not screw the base plates onto the foundations yet Diagram 2 Foundation plan Reinforcement plan Concrete foundation with reinforcement Foundation BSt 500S Stirrups Ø 8 mm lengthwise and cross Concrete cover h 3 cm Concrete quality class C20 25 ground level 4484 400 450 2234 1309 2368 2512...

Страница 3: ...red drop height in accordance with EN 16630 Critical drop height 1350 mm Recommended surface material sand wood chips gravel synth impact protection Grass is not allowed With a smaller installation depth special edition we recommend synthe tic impact protection In this case make sure that protruding parts e g screws gusset plates are covered with appropriate fall protection 14 Do not allow to use ...

Страница 4: ...f such corrosion occur on stainless steel parts they are fine to remove with an abrasive 240 grit Please take care when transporting and setting up the fact that the compo nents are made of stainless steel with no normal steel parts in contact In order to preserve a good visual appearance of your stilum fitness equip ment over a long period one should take care of maintenance of the stain less sur...

Страница 5: ...aired See EN 1176 Bbl 1 2019 01 4 2 7 6 Dry cracks in wood elements as a consequence of weather conditions are not to be considered as dange rous openings in terms of the standard due to the fact that the shape of the cracks tapering towards the inside makes it almost impossible for fingers to get trapped in them MAINTENANCE To ensure a long life of stilum fitness equipment wooden surfaces should ...

Страница 6: ...t cotton cloth Then let the freshly glazed wood dry for at least one day and prohibit the use of the equipment for this duration General Information DIN 16630 2015 06_4 1 DIN EN1176 specifies that fitness equipment should not be installed in the imme diate vicinity of children s playground equipment In cases where they are erected in playgrounds or similar establishments near children s playground...

Отзывы: