background image

State:  16.06.2021 p. 5

 

Mounting instructions for „Calisthenics“ robinia  

Item-No. 55 1520 602

©  stilum GmbH, Gewerbegebiet Larsheck, D-56271 Kleinmaischeid  •  Tel. +49 (0) 2689 92790-0  •  All rights and product modifications reserved.     

health

Diagram 5: Foundation plan of the instruction sheet

Do not use any chlorid or hydrochloric containing cleaning products nor 
scouring powder, bleaching - or silver polish cleaner. Cleaning intervals de

-

pend on type and degree of soiling as well as on demands made on optical 
characteristics. Therefore cleaning is advisable at intervals of six to twelve 
months – whereby in the case of strong soiling it is appropriate to clean the 
fitness equipment at intervals of three to six months.

WOOD

NOTE:

 For all fitness equipment with wooden elements, it cannot be ruled 

out that dry cracks may develop. These natural changes of wood are 
dependent on climate conditions as well as on the age and usage of the 
fitness equipment. Longer dry periods may lead to more dry cracks. 
This development, however, does not represent a quality defect. Static pro

-

perties of the equipment are not impaired. 

See EN 1176 Bbl 1:2019-01 4.2.7.6: Dry cracks in wood elements as a 
consequence of weather conditions are not to be considered as dange-
rous openings in terms of the standard due to the fact that the shape of the 
cracks (tapering towards the inside) makes it almost impossible for fingers 
to get trapped in them. 

MAINTENANCE: 

To ensure a long life of stilum fitness equipment, wooden 

surfaces should be regularly re-glazed. This provides the wooden surfaces 
with the necessary protection and preserves the look. Areas which are not 
exposed to rain should be regularly freed from deposits.

300

640

300

388

300

 768 

150

2010

 2184 

OHNE SCHRIFTLICHE ZUSTIMMUNG DER KAISER GMBH DARF DIESE 

TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT, NOCH DRITTEN MITGETEILT ODER 

ZUGÄNGLICH GEMACHT WERDEN, NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER- 

WENDET WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.

1

 

Instruktionstafel 600x960

Benennung

Gepr.

Blatt

Datum

Projekt

Gez.

Zeichnungsnummer

1:20

A3

Name

Name

Fundamentplan

2204-00-00

Maßstab

Schramm

22.11.18

 

 

Gewerbegebiet Larsheck

56271 Kleinmaischeid

Deutschland

Beton

concrete
gewachsenes Erdreich

natural ground

Legende

stoßdämpfender Boden

shock-absorbing floor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
ES

09.12.20

beliebiger Boden

A

Datum

Änderung

Rev

beliebiger Boden

optional floor

Содержание Calisthenics 55 1520 602

Страница 1: ...m No 55 1520 602 stilum GmbH Gewerbegebiet Larsheck D 56271 Kleinmaischeid Tel 49 0 2689 92790 0 All rights and product modifications reserved health Diagram 1 Overall view of the fitness equipment dip module push up module climbing module leg workout module pull up module ...

Страница 2: ...odule to the clamps diagram 3c Pay attention to the exact installation according to diagram 1 2 and 3d Note Do not screw the base plates onto the foundations yet Diagram 2 Foundation plan Reinforcement plan Concrete foundation with reinforcement Foundation BSt 500S Stirrups Ø 8 mm lengthwise and cross Concrete cover h 3 cm Concrete quality class C20 25 ground level 4484 400 450 2234 1309 2368 2512...

Страница 3: ...red drop height in accordance with EN 16630 Critical drop height 1350 mm Recommended surface material sand wood chips gravel synth impact protection Grass is not allowed With a smaller installation depth special edition we recommend synthe tic impact protection In this case make sure that protruding parts e g screws gusset plates are covered with appropriate fall protection 14 Do not allow to use ...

Страница 4: ...f such corrosion occur on stainless steel parts they are fine to remove with an abrasive 240 grit Please take care when transporting and setting up the fact that the compo nents are made of stainless steel with no normal steel parts in contact In order to preserve a good visual appearance of your stilum fitness equip ment over a long period one should take care of maintenance of the stain less sur...

Страница 5: ...aired See EN 1176 Bbl 1 2019 01 4 2 7 6 Dry cracks in wood elements as a consequence of weather conditions are not to be considered as dange rous openings in terms of the standard due to the fact that the shape of the cracks tapering towards the inside makes it almost impossible for fingers to get trapped in them MAINTENANCE To ensure a long life of stilum fitness equipment wooden surfaces should ...

Страница 6: ...t cotton cloth Then let the freshly glazed wood dry for at least one day and prohibit the use of the equipment for this duration General Information DIN 16630 2015 06_4 1 DIN EN1176 specifies that fitness equipment should not be installed in the imme diate vicinity of children s playground equipment In cases where they are erected in playgrounds or similar establishments near children s playground...

Отзывы: