► Remove container.
1
1
2
0000098909_001
► Turn filter basket (1) counterclockwise and
remove it.
► Remove paper filter (2).
► Remove coarse dirt on the outside of the
paper filter. (2).
► Knock off the paper filter (2).
► Knock off the filter basket (1).
► Rinse the filter basket (1) under running water
and allow to air dry.
► Install the paper filter (2) in the filter basket (1).
► Attach the filter basket (1) and turn it clockwise
until it engages.
15.3
Cleaning the Battery
► Clean the battery with a damp cloth.
15.4
Cleaning the Charger
► Disconnect the mains plug from the power
supply.
► Clean the charger with a damp cloth.
► Clean the charger’s electrical contacts with a
paintbrush or a soft brush.
16 Repairing
16.1
Repairing Hand Vacuum, Bat‐
tery and Charger
The hand vacuum, the battery and the charger
cannot be repaired by the user.
► If the hand vacuum is damaged: Do not use
the hand vacuum and contact your STIHL
dealer for assistance.
► If the battery has a malfunction or is damaged:
Replace the battery.
► If the charger has a malfunction or is dam‐
aged: Replace the charger.
► If the connecting cable has a malfunction or is
damaged: Do not use the charger and have
the connecting cable replaced by a STIHL
dealer.
17 Troubleshooting
17.1
Remedying Faults in the Hand Vacuum or Battery
Fault
LEDs on the
hand vacuum
Cause
Remedy
Hand vacuum
does not start
when switched
on.
1 LED flashing
green.
State of charge of the
battery is too low.
► Charge the battery.
1 LED emits red
light.
The battery is too
warm or too cold.
► Remove the battery.
► Allow the battery to cool down or warm
up.
3 LEDs flash
red.
There is a fault in the
hand vacuum.
► Remove battery and reinsert it.
► Switch on the hand vacuum.
► If 3 LEDs continue to flash red: Do not
use the hand vacuum and contact your
STIHL dealer for assistance.
3 LEDs emit red
light.
The hand vacuum is
too warm.
► Remove the battery.
► Wait for the hand vacuum to cool down.
4 LEDs
flash red.
There is a fault in the
battery.
► Remove the battery.
► Clean electrical contacts in the battery
compartment.
► Insert battery.
► Switch on the hand vacuum.
► If 4 LEDs continue to flash red: Do not
use the battery and contact your STIHL
dealer for assistance.
No electrical contact
between hand
vacuum and battery.
► Remove the battery.
► Clean electrical contacts in the battery
compartment.
► Insert battery.
English
16 Repairing
32
0458-006-9621-B