The high-pressure cleaner can only be
used in suction operation with the
suction set (special accessory).
NOTICE
As a rule, it is advisable to use a water
filter.
N
Connect the machine to the
pressurized water supply and start it
up briefly in accordance with the
Instruction Manual
N
Switch off the machine
N
Disconnect the spray attachment
from the high-pressure hose
N
Unscrew the hose connector from
the water connection
N
Connect the suction set to the water
connection with the included
connector
Always use the connector included in
the suction set. The hose connectors
included as standard with the high-
pressure cleaner are not leakproof in
suction operation and thus are not
suitable for drawing in water.
N
Fill the suction hose with water and
immerse the suction cup of the
suction hose in the water tank – do
not use dirty water
N
Hold down the high-pressure hose
by hand
N
Switching on the machine
N
Wait until a steady jet exits the high-
pressure hose
N
Switch off the machine
N
Connect spray attachment
N
Switch on the machine with the
spray gun open
N
Actuate the spray gun several times
briefly in order to bleed the air out of
the machine as quickly as possible
The voltage and frequency of the
machine (see rating plate) must match
the voltage and frequency of the power
connection.
The minimum fuse protection of the
power connection must comply with the
specifications – see "Specifications".
The machine must be connected to the
power supply via an earth-leakage
circuit breaker to disconnect the power
supply if the differential current to earth
exceeds 30 mA for 30 ms.
The power connection must correspond
to IEC 60364
-
1 and relevant national
regulations.
When the machine is switched on,
voltage fluctuations that occur under
unfavorable mains conditions (high
power line impedance) may negatively
affect other connected electrical
appliances. Trouble is not anticipated at
power line impedances less than
0.15 Ω.
The extension cord must have the
following minimum cross-section
depending on the mains voltage and
cord length.
Connecting to a pressureless
water supply
Connecting to Power Supply
Cord length
Minimum cross-
section
400 V / 3~:
400 V – 415 V / 3~:
up to 20 m
1.5 mm
2
20 m to 50 m
2.5 mm
2
230 V / 1~:
230 V / 3~:
up to 20 m
2.5 mm
2
Содержание RE 232
Страница 1: ...STIHL RE 232 272 PLUS 282 PLUS Instruction Manual...
Страница 2: ......
Страница 37: ...RE 232 RE 272 PLUS RE 282 PLUS English 35...
Страница 38: ...RE 232 RE 272 PLUS RE 282 PLUS English 36...
Страница 39: ......
Страница 40: ...www stihl com 04586520121A 0458 652 0121 A 0458 652 0121 A englisch G...