24
English / USA
FS 100 RX
:
Unscrew and dry off the spark plug.
:
Open the throttle wide.
:
Crank the engine several times with
the starter to clear the combustion
chamber.
:
Refit the spark plug. Connect the
spark plug boot (press it down
firmly).
:
Move the slide control to
START
.
:
Set the choke knob to
e
–
even if engine is cold.
:
Now start the engine.
Throttle cable adjustment
:
Check adjustment of throttle cable –
see "Adjusting the Throttle Cable".
Tank run until dry
:
After refueling, press the fuel pump
bulb at least five times – even if bulb
is filled with fuel.
:
Set choke knob according to engine
temperature.
:
Now start the engine.
During break-in period
A factory new machine should not be run
at high revs (full throttle off load) for the
first three tank fillings. This avoids
unnecessary high loads during the
break-in period. As all moving parts
have to bed in during the break-in
period, the frictional resistances in the
engine are greater during this period.
The engine develops its maximum
power after about 5 to 15 tank fillings.
During operation
After a long period of full-throttle
operation, allow engine to run for a while
at idle speed so that the heat in the
engine can be dissipated by flow of
cooling air. This protects engine-
mounted components (ignition,
carburetor) from thermal overload.
After finishing work
Wait for engine to cool down. Drain the
fuel tank. Store the machine in a dry
place. Check tightness of nuts and
screws (not adjusting screws) at regular
intervals and retighten as necessary.
Dirty air filters reduce engine power,
increase fuel consumption and make
starting more difficult.
If there is a noticeable loss of engine
power:
:
Set the choke knob to
g
.
:
Take out the screw (
1
) and remove
the filter cover (
2
).
:
Clean away loose dirt from around
the filter.
:
Grip the filter element (
3
) at the
notch (arrow) in the filter housing (
4
)
and take it out.
:
Fit a new filter element. As a
temporary measure you can knock it
out on the palm of your hand or blow
it out.
Do not wash.
:
Replace any damaged parts.
:
Install filter element in the filter
housing.
:
Refit the filter cover.
:
Insert the screw and tighten it down
firmly.
Operating Instructions
Cleaning the Air Filter
1
266BA009 KN
2
4
Содержание FS 100 RX